Maximum Current Flows
3.
Wiring Auxiliary Devices
Use the Auxiliary Power AUX (+) COM (-) terminals to power PIRs, glass-break detectors (4-wire
types), smoke detectors, audio switches, photoelectric systems and/or any device that requires a 12V
DC power supply.
4ANote:
If the auxiliary outputs are overloaded (exceed 800/1500mA) and are shut down, you must
disconnect all loads from the outputs for a period of at least 10 seconds before you reconnect any
load to the auxiliary outputs.
4.
Wiring Internal Bell
The Bell/LS terminal provides power to the internal siren. When connecting an internal sounding
device, pay attention to the polarity.
It is important to position the BELL/LS Dip Switch SW1 correctly. The position varies depending on
the type of internal siren.
Note:
To avoid bell loop trouble, if no connections are made to an internal siren, use a 2.2KΩ resistor in its
place.
5.
Wiring Bell Tamper
Connect the bell tamper to the BELL TMP and COM terminals on
the main panel using 2.2KΩ resistors in serial.
BELL
TMP
COM
2.2
K EOL
RESISTOR
BELL TAMPER