General settings, Main system timers, Set up users – RISCO Group LightSYS Ver 2.xx User Manual
Page 18: Keyfobs and 2-way slim keypads
•
The restore events that will be sent
•
The operations the user will be able to perform through remote connection via phone,
SMS or the Cloud
Note:
The actual destinations (telephone numbers, email addresses) are not defined within the
Programming menu.
General Settings
There are several system-wide parameters that define how the LightSYS works. All these
parameters are set with default values that apply for most installations. If you wish to modify the
default settings, go through the menus to program any other system parameter.
1. Main System Timers
1.
From the main installer programming menu select 1) System 1)Timers
2. Select options 01 and 02 to define exit entry times.
3. Select option 03 to define siren duration time.
4. Scroll through the other options of the menu.
2. Set Up Users
As the installer, you must set up the system’s users. The owner (Grand Master) will be allowed to
subsequently set their code.
1. From the main installer programming menu select 4) Codes.
2. Under the 1) User option define for each user its authority level and the partitions it can
control with his code.
3. Change the default installer code under the option 3) Installer.
Keyfobs and 2-Way Slim Keypads
Each keyfob and keypad can be set up to perform different system functions and control different
utility outputs. Up to eight keyfobs (1-way and 2-way) and four 2-way keypads can be enrolled in
the system. The programming options vary according to whether the device is 1-way or 2-way.
Each user can be assigned with a single keyfob.
Step 1: Allocating Keyfobs and Slim Keypads
•
Allocate and calibrate the devices as described in Wireless Zones section (page 14)
Step 2: Setting Keyfob Options [for both 1-way and 2-way keyfobs]
a. From the installer (Programming) menu, select 8) Devices > 2) Keyfob > 1) Select
User
b. Select the user that the keyfob belongs to. and then press
.
c. Use the arrow keys to scroll between menus and the
key to select menu
options for the 1-way and 2-way keyfobs:
Options for the 1-Way Keyfob:
For each button (1-4), define its function, from the available options (see table below for
a description of options). Use the respective “Quick key” to designate an option for each
button:
18