Operating warnings – MCZ Club HYDRO 15 kW User Manual
Page 5

PELLET STOVES
Chapter 1
INSTALLATION AND USE MANUAL
page
5
Warnings and guarantee conciliations
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
disconnected from the mains electricity supply, by turning
off the main switch located on the back of the stove, or
by unplugging the supply cable.
The stove must be connected to an electrical system
which is equipped with an earth conductor.
The system must be of adequate rated capacity for the
stated electrical power of the stove.
Incorrect installation or faulty maintenance (not
conforming to the requirements set out in this booklet)
can cause harm to people, animals or property. In such
cases MCZ is absolved from any civil or criminal
responsibility.
Live electrical parts: only power the product after
completing assembly.
Disconnect the product from the 230V power supply
before performing any maintenance operation.
IF ANY SMOKE SPILLAGE IS SEEN WITHIN THE
ROOM OR THE APPLIANCE SUFFERS FROM AN
EXPLOSIVE IGNITION PLEASE TURN OFF THE
APPLIANCE, VENTILATE THE ROOM AND CONTACT
THE
INSTALLER/
SERVICE
ENGINEER
IMMEDIATELY.
1.2. OPERATING WARNINGS
Shut the stove down in the event of a breakdown
or bad running and contact the engineer
immediately.
Pellets must not be fed manually into the burner
– this wrong behaviour can generate an
abnormal amount of unburned gas, with a risk of
explosion in the chamber.
Accumulated unburnt pellets in the burner after a
failed ignitions must be removed before lighting.
Failure too clean and maintain the brazier can result in
improper running and explosions within the stove. Make
sure you remove and clear the holes in the brazier and
any loose encrustations every time you empty the ash
from the stove or every time you have a failed
ignition.Make sure that the holes in the brazier are
never reduced in size as this will affect the safe
performance of the stove if not maintained.
Do not wash the inside of the stove with water.
Do not wash the stove with water. The water could get
inside the unit and damage the electrical insulation and
cause electric shocks.
A carbon monoxide alarm must be fitted in the
room where the appliance is sited Refer too ADJ
part 2.34 through too 2.36 page 41
Do not expose your own body to hot air for extended
periods. Do not overheat the room you are in and
where the stove is installed. This could cause injuries
and health problems.
Do not expose plants or animals directly to a current of
hot air. Both plants and animals could be harmed by it.
Do not put any fuels in the hopper but wood pellets.
Install the stove in a location which is suitable for
firefighting, and equipped with all services such as air
ONLY FOR UK
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency