beautypg.com

Example installation diagrams, Ego/star/suite/club/musa), Pellet stoves chapter 3 – MCZ Club HYDRO 15 kW User Manual

Page 37: Installation and use manual

background image

PELLET STOVES

Chapter 3

INSTALLATION AND USE MANUAL

page

37

Installation and assembly

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

3.6. EXAMPLE INSTALLATION DIAGRAMS

The following diagrams are to be used only as a

guideline. For proper connection, always follow the

notes for the plumbing and heating installer. The

plumbing system must meet local, regional or

national requirements. Installation and verification of

operation is to be performed only by specialized,

authorized personnel.
MCZ will not be held liable for non-compliance with

the provisions listed above.

3.6.1.

Installation diagram for heating system without domestic hot water kit

(EGO/STAR/SUITE/CLUB/MUSA)

PERFORMANCE:

HEATING WITH STOVE

S

T

VS

P

VE

V

Vsc

T

SE

230V 50HZ

RA

RA

RA

RA

RP

Flt

A

V

V

M

SYSTEM DELIVERY

PRESSURE SAFETY DISCHARGE

SYSTEM RETURN

SYSTEM REFILL

CONFIGURATION: STAR/EGO/SUITE/CLUB/MUSA WITH DOMESTIC HOT WATER KIT

SYSTEM OF SYSTEM WITH CLOSED TANK ONLY FOR HEATING BY MEANS OF RADIATORS

SIGNATURFORKLARING:

SE Electronic card

S

Automatic vent

M

Pressure gauge

VS Vent valve, 3 bar

V

Valve

P

Pump

VD One-way valve

T

Measurement of boiler temperature

VE Expansion tank, 1.5 bar of 6 l

W 3-way motorized valve

SC Plate heat exchanger

F

Flow switch

C

Methane gas boiler

B

Boiler

BA Storage boiler

RA Radiators

PR Radiant panels

PS Solar panels

A

Pounding absorber

RP Pressure reduction valve

Vsc Boiler/system discharge valve

Flt System filter

Add Softener