Connection of smoke discharge pipe – MCZ Club HYDRO 15 kW User Manual
Page 12

PELLET STOVES
Chapter 2
INSTALLATION AND USE MANUAL
page
12
Theoretical notions for installation
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
2
1
Be protected by a grille, metal mesh or suitable guard, as long as
this does not reduce the area below the minimum.
be positioned in such a way as to be impossible to obstruct
2.5. CONNECTION OF SMOKE DISCHARGE PIPE
We recommend the use 100mm single wall connecting flue pipe.
All exterior flue or flue used internaly above 1.8m should be twin wall
insulated pipe installed in accordance with ADJ reference page 23
section 1.31 and 1.32 and 1.33 & Hetas regulations.
The combustion chamber works in low pressure. The smoke duct for
the discharge of fumes will also be under low pressure when connected
to an efficient flue pipe as directed.
Pipes and unions with suitable gaskets must always
be used, to guarantee a hermetic seal.
All sections of the smoke duct must be inspectable and
removable to enable periodic internal cleaning. Tee
connectors with inspection caps should be used.
Position the stove bearing in mind all the instructions and considerations
above.
ONLY FOR UK
Example of pellet stove installation
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency