PELLET STOVES

Chapter 3

INSTALLATION AND USE MANUAL

page

35

Installation and assembly

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

End piece with a
filling tap (D)
and pressure gauge (M)
(accessory)

Grey plug loosened
1 turn

Red plug blocked

3.4.2.

System filling

To fill the system, the stove can be equipped with an end piece

(optional)

with a non-return valve (D), for manual filling of the heating

system (if the

optional

is not installed, the filling tap on the main boiler

will be used). During this operation, any air in the system is released

from the automatic vent valve located under the top.
To ensure the valve vents correctly, it is advisable to loosen the grey

cap one turn and to keep the red cap blocked

(see figure)

The filling pressure of the system WHEN COLD must be

1 bar.
During operation, if the system pressure drops (due to evaporation of

dissolved gases in the water) to values lower than the minimum

indicated above, the user must use the filling tap to bring the pressure
back up to its normal pressure.
For proper operation of the stove WHEN HOT, the pressure in the

boiler must be1.5 bar.
To monitor system pressure, the end piece

(optional)

is

equipped with a pressure gauge (M).
Upon completion of this operation, always close the tap.

3.4.3.

Water characteristics

The characteristics of the water used to fill the system are very

important to prevent the build-up of mineral salts and the formation of

incrustations along the pipes, in the boiler and in the heat exchangers.
Therefore,

please

GET

YOUR

PLUMBER'S

ADVICE

CONCERNING:

Hardness of water circulating in the system, to prevent

problems of incrustation and limescale, especially in the

domestic water heat exchanger. (> 25° French)

Installation of a water softener (if water hardness

exceeds 25° French)

Filling the system with treated water (demineralised).

Possibly providing an anti-condensation circuit.

Installation of plumbing bumpers to prevent banging

along the fittings and pipes.

If you have very extensive systems, with a large amount of water, or
which require frequent refilling, the installation of water softening

systems.

It should be remembered that incrustations

drastically reduce performance due to low thermal

conductivity.

Filling tap (D)
Pressure gauge (M)

Vent valve under the top