beautypg.com

Pre-lighting check, Loading the pellets, Supplementary hopper conduit (accessory) – MCZ Club HYDRO 15 kW User Manual

Page 5: Safety

background image

PELLET STOVES

Chapter 4

INSTALLATION AND USE MANUAL

page

5

Operation

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

A

4.2. PRE-LIGHTING CHECK

Check that all the safety conditions described above have been met.
Make sure you have read and completely understood the contents of

this instruction booklet.
Remove any components which might burn from the firebox and from

the glass (various instructions and adhesive labels).
Check that the grate A is properly positioned and rests correctly on the

base.

After long periods of disuse, remove from the hopper (using

a vacuum cleaner with an extension) any remains of

pellets which have lain there for some time, since they may

have absorbed moisture, which changes their original
characteristics and makes them unsuitable for burning.

4.3. LOADING THE PELLETS

Fuel is loaded from the upper part of the stove by opening a door. Pour

the pellets in the hopper. When empty, it will hold slightly more than a

15 kg sack.
This is easier if performed in two steps:

Pour half of the contents into the hopper and wait for the fuel

to settle on the bottom.

Then pour in the rest

Never remove the protection grille in the hopper.

When filling, do not let the sack of pellets touch any

hot surfaces.
Do not place any type of fuel in the hopper other than

pellets that are compliant with the specifications

provided previously.

4.4. SUPPLEMENTARY

HOPPER

CONDUIT

(accessory)

On the rear part of the stove, in correspondence of the pellet hopper, a

pre-cut knockout panel has been provided for connecting a conduit for a

supplementary hopper (accessory) externally of the stove. To open the
pre-cut knockout panel, strike it with a rubber mallet.
Place the conduit plate on the stove body so that the conduit itself faces

upward. Fasten the conduit to the stove body using the 4 screws

provided with the accessory.

4.5. SAFETY

PROCEDURE TO FOLLOW IF ANY SMOKE SPILLAGE IS SEEN

WITHIN THE ROOM OR THE APPLIANCE SUFFERS FROM AN

EXPLOSIVE IGNITION PLEASE TURN OFF THE APPLIANCE,

VENTILATE THE ROOM AND CONTACT THE INSTALLER/

SERVICE ENGINEER IMIDIATLEY.