Pre-lighting check, Loading the pellets, Supplementary hopper conduit (accessory) – MCZ Club HYDRO 15 kW User Manual
Page 5: Safety

PELLET STOVES
Chapter 4
INSTALLATION AND USE MANUAL
page
5
Operation
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
A
4.2. PRE-LIGHTING CHECK
Check that all the safety conditions described above have been met.
Make sure you have read and completely understood the contents of
this instruction booklet.
Remove any components which might burn from the firebox and from
the glass (various instructions and adhesive labels).
Check that the grate A is properly positioned and rests correctly on the
base.
After long periods of disuse, remove from the hopper (using
a vacuum cleaner with an extension) any remains of
pellets which have lain there for some time, since they may
have absorbed moisture, which changes their original
characteristics and makes them unsuitable for burning.
4.3. LOADING THE PELLETS
Fuel is loaded from the upper part of the stove by opening a door. Pour
the pellets in the hopper. When empty, it will hold slightly more than a
15 kg sack.
This is easier if performed in two steps:
Pour half of the contents into the hopper and wait for the fuel
to settle on the bottom.
Then pour in the rest
Never remove the protection grille in the hopper.
When filling, do not let the sack of pellets touch any
hot surfaces.
Do not place any type of fuel in the hopper other than
pellets that are compliant with the specifications
provided previously.
4.4. SUPPLEMENTARY
HOPPER
CONDUIT
(accessory)
On the rear part of the stove, in correspondence of the pellet hopper, a
pre-cut knockout panel has been provided for connecting a conduit for a
supplementary hopper (accessory) externally of the stove. To open the
pre-cut knockout panel, strike it with a rubber mallet.
Place the conduit plate on the stove body so that the conduit itself faces
upward. Fasten the conduit to the stove body using the 4 screws
provided with the accessory.
4.5. SAFETY
PROCEDURE TO FOLLOW IF ANY SMOKE SPILLAGE IS SEEN
WITHIN THE ROOM OR THE APPLIANCE SUFFERS FROM AN
EXPLOSIVE IGNITION PLEASE TURN OFF THE APPLIANCE,
VENTILATE THE ROOM AND CONTACT THE INSTALLER/
SERVICE ENGINEER IMIDIATLEY.
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency