Shutting the stove down (end of season), Check of internal components – MCZ Club HYDRO 15 kW User Manual
Page 37

PELLET STOVES
Chapter 5
INSTALLATION AND USE MANUAL
page
37
Maintenance and cleaning
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
Figure 18 – Switch with fuse box
6.2.3.
Shutting the stove down (end of season)
In the period when the stove is out of use it must be
disconnected from the electricity mains. For greater safety,
especially if there are children around, we recommend
removing the power cable from the rear of the stove.
(Figure 17)
Before placing the stove in storage, you should remove all pellets from
the hopper with a vacuum cleaner with a long extension. If the fuel is
left in the hopper, it may get damp, stick together, and be difficult to
light at the beginning of the next season
If the stove is removed form its place of installation it MUST be
placed in a location that is protected from atmospheric agents.
If pressing the main switch (located on the back of the stove) does not
make the control panel display light up, it could mean that the service
fuse needs replacing.
ATTENTION!
Disconnect the electrical cable.
On the rear of the stove there is a fuse holding compartment which is
located underneath the supply socket. With a screwdriver open the
cover of the fuse holding compartment, and replace the fuse if
necessary (3.15 AT delayed type).
Figure 18
Plug the unit back in and press the main switch.
If the problem persists or occurs again, contact your MCZ retailer.
6.3. CHECK OF INTERNAL COMPONENTS
ATTENTION!
The check of the internal electromechanical
components must be carried out only by qualified
personnel with technical knowledge of electricity and
combustion. If necessary, contact authorized MCZ
retailers.
We recommend that an annual maintenance service is carried out,
preferably under a programmed service contract. The essential part of
this service is a visual and functional check on the following
components:
Reduction motor
Smoke expulsion fan
Smoke sensor
Heat-exchanger fan
Ignition sparkplug
Resettable pellet thermostat
Room temperature sensor
Motherboard / service card
Fuses protecting panel - motherboard - services card
Wiring
Figure 17 – Disconnect the stove from the electrical
mains
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency