beautypg.com

Shutting the stove down (end of season), Check of internal components – MCZ Club HYDRO 15 kW User Manual

Page 37

background image

PELLET STOVES

Chapter 5

INSTALLATION AND USE MANUAL

page

37

Maintenance and cleaning

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

Figure 18 – Switch with fuse box

6.2.3.

Shutting the stove down (end of season)

In the period when the stove is out of use it must be

disconnected from the electricity mains. For greater safety,

especially if there are children around, we recommend

removing the power cable from the rear of the stove.

(Figure 17)

Before placing the stove in storage, you should remove all pellets from

the hopper with a vacuum cleaner with a long extension. If the fuel is

left in the hopper, it may get damp, stick together, and be difficult to

light at the beginning of the next season
If the stove is removed form its place of installation it MUST be

placed in a location that is protected from atmospheric agents.

If pressing the main switch (located on the back of the stove) does not

make the control panel display light up, it could mean that the service
fuse needs replacing.

ATTENTION!
Disconnect the electrical cable.

On the rear of the stove there is a fuse holding compartment which is

located underneath the supply socket. With a screwdriver open the

cover of the fuse holding compartment, and replace the fuse if

necessary (3.15 AT delayed type).

Figure 18

Plug the unit back in and press the main switch.
If the problem persists or occurs again, contact your MCZ retailer.

6.3. CHECK OF INTERNAL COMPONENTS

ATTENTION!
The check of the internal electromechanical

components must be carried out only by qualified

personnel with technical knowledge of electricity and

combustion. If necessary, contact authorized MCZ

retailers.


We recommend that an annual maintenance service is carried out,

preferably under a programmed service contract. The essential part of

this service is a visual and functional check on the following

components:

Reduction motor

Smoke expulsion fan

Smoke sensor

Heat-exchanger fan

Ignition sparkplug

Resettable pellet thermostat

Room temperature sensor

Motherboard / service card

Fuses protecting panel - motherboard - services card

Wiring


Figure 17 – Disconnect the stove from the electrical

mains