First lighting, Start-up/shutdown from the control panel, Note on first ignition – MCZ Club HYDRO 15 kW User Manual
Page 12

PELLET STOVES
Chapter 4
INSTALLATION AND USE MANUAL
page
12
Operation
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
B
Esc Set
< Setting >
Esc Set
< Setting >
21.0°C 21.04
OFF
Mode:AUTO Menu
Temp:22°C Fan:A
Esc Set
<
>
Screw feeder loading
Esc Set
<
>
Screw feeder loading
Esc ON Set
<
>
Screw feeder loading
To adjust it: press any button; press the “MENU”
button; using the buttons for scrolling, display the
“SET TEMP.H
2
O” screen; press the “SET” button; set
the desired temperature using the buttons for
scrolling “ < > ”; confirm the temperature with the
“OK” button.
4.10. FIRST LIGHTING
4.10.1. Start-up/shutdown from the control panel
The stove is ignited and shutdown by pressing key B on the control
panel for 2 seconds.
After a start-up phase that lasts about 15 minutes, the stove will come
up to full operating power.
After the stove is shut down by pressing button B on the control panel,
the cooling-off procedure begins. This includes the interruption of fuel
loading, the cleaning of the grate and the continuation of ventilation
until the stove is sufficiently cold. This phase may last from 20 to 40
minutes depending on how long the stove was lit and its position.
4.10.2. Note on first ignition
The first attempt at ignition may not be successful,
since the feeder screw is empty and it is not always
able to fill the grate with required amount of pellets
in time to ensure normal ignition.
If the screw feeder is empty, use the control panel to
activate manual screw feeder loading.
CANCEL THE ALARM CONDITION FROM THE
CONTROL PANEL (see paragraph 4.14)., REMOVE
PELLETS IN THE GRATE AND REPEAT LIGHTING
After repeated attempts at lighting, if there is no flame even though
pellets are flowing normally, check that the grate is correctly positioned.
It must be placed where it adheres perfectly to its housing and
free of any ash incrustations. If after this check no abnormalities
are found, it means that there may be a problem with the stove
components or that installation may not have been carried out correctly.
REMOVE THE PELLETS FROM THE BURNER AND
CONTACT AN AUTHORISED MCZ TECHNICIAN.
Screw feeder loading
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency