Operation

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

B

Esc Set
< Setting >

Esc Set
< Setting >

21.0°C 21.04
OFF

Mode:AUTO Menu
Temp:22°C Fan:A

Esc Set
<

>

Screw feeder loading

Esc Set
<

>

Screw feeder loading

Esc ON Set
<

>

Screw feeder loading

To adjust it: press any button; press the “MENU”

button; using the buttons for scrolling, display the

“SET TEMP.H

2

O” screen; press the “SET” button; set

the desired temperature using the buttons for

scrolling “ < > ”; confirm the temperature with the

“OK” button.

4.10. FIRST LIGHTING

4.10.1. Start-up/shutdown from the control panel

The stove is ignited and shutdown by pressing key B on the control

panel for 2 seconds.

After a start-up phase that lasts about 15 minutes, the stove will come
up to full operating power.
After the stove is shut down by pressing button B on the control panel,

the cooling-off procedure begins. This includes the interruption of fuel

loading, the cleaning of the grate and the continuation of ventilation

until the stove is sufficiently cold. This phase may last from 20 to 40

minutes depending on how long the stove was lit and its position.

4.10.2. Note on first ignition

The first attempt at ignition may not be successful,

since the feeder screw is empty and it is not always

able to fill the grate with required amount of pellets

in time to ensure normal ignition.

If the screw feeder is empty, use the control panel to

activate manual screw feeder loading.

CANCEL THE ALARM CONDITION FROM THE

CONTROL PANEL (see paragraph 4.14)., REMOVE

PELLETS IN THE GRATE AND REPEAT LIGHTING

After repeated attempts at lighting, if there is no flame even though

pellets are flowing normally, check that the grate is correctly positioned.

It must be placed where it adheres perfectly to its housing and

free of any ash incrustations. If after this check no abnormalities
are found, it means that there may be a problem with the stove

components or that installation may not have been carried out correctly.

REMOVE THE PELLETS FROM THE BURNER AND

CONTACT AN AUTHORISED MCZ TECHNICIAN.



Screw feeder loading