PELLET STOVES

Chapter 6

INSTALLATION AND USE MANUAL

page

40

Problems / Causes / Solutions

Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited

PROBLEM

POSSIBLE CAUSES

REMEDY

In

the

automatic

position

the

stove

always runs at full

power.

1. Room thermostat set to maximum.

2. Temperature sensor defective.

3. Control panel defective or broken.

1. Reset the thermostat temperature.

2. Check the operation of the sensor

and replace if necessary.

3. Check the panel and replace if

necessary.

The stove does not run 1. Lack of electricity supply.

2. Pellet sensor in lockout.

3. Fuse blown.

1. Check that the electric socket is plugged

in and that the main switch is in position

“I”.

2. Clear lockout by resetting the rear

thermostat, replace the thermostat if

it happens again.

3. Replace the fuse.


ANOMALIES RELATED TO THE PLUMBING CIRCUIT

PROBLEM

POSSIBLE CAUSES

REMEDY

No

increase

in

temperature

with

stove in operation

1. Incorrect combustion adjustment.
2. Boiler / system dirty.
3. Insufficient stove power.

4. Poor pellet quality

1. Check recipe and parameters.
2. Check and clean the boiler.
3. Check that the stove is properly

sized for the requirements of the

system.

4. Use MCZ pellets

Condensation

in

boiler

1. Incorrect temperature setting.
2. Insufficient fuel consumption.

1.

Set the stove to a higher

temperature.

2.

Check the recipe and/or technical

parameters.

Radiators

cold

in

winter

1. Room thermostat (local or remote)

set too low. If remote thermostat,

check if it is defective.

2. Circulator does not run because

blocked.

3. Circulator does not run.

4. Radiators have air in them

1.

Set to higher temperature or

replace. (if remote)

2.

Free up the circulator by removing

the plug and turning the shaft with a

screwdriver.

3.

Check the electrical connections of

the circulator; replace if necessary.

4.

Vent the radiators

Hot water is not

provided

1. Circulator (pump) blocked

1.

Free the circulator (pump)

ATTENTION!
The operations

in italics

must be carried out by

specialised MCZ personnel.
The manufacturer refuses to accept any responsibility

and the guarantee lapses if this condition is not

respected.