MESSAGE ON
DISPLAY
TYPE OF PROBLEM
SOLUTION
A01
The fire does not ignite.
Check the level of pellets in the tank.
Check that the brazier rests correctly in its seat and has
no visible deposits or unburnt pellets.
Check whether the ignition plug becomes hot.
Empty and clean the brazier before relighting.
A02
Fire extinguishes abnormally
It derives from a shutdown due to lack of fuel (hopper
empty).
A03
Pellet tank temperature exceeds foreseen
safety limit.
Overheating of the stove body
The structure is too hot because the product has been
operating for too long at maximum power, or it is
poorly ventilated, or the air fans are faulty. When the
stove is sufficiently cold, press button B of the control
panel to cancel the alarm A03. Once the alarm is
cancelled it is possible to relight the stove normally.
A04
The temperature of the smoke discharge has
exceeded pre-set safety limits
The stove will shut off automatically. Let the stove cool
off for a few minutes, then re-light it.
Control the exhaust of the smoke the type of pellet
being used.
A05
Flue pipe obstruction - wind - door open.
Check fume conduit and door closure.
A06
The smoke extractor is not able to provide the
primary air required for combustion.
Draught difficulties or clogging of grate.
Check whether the grate is clogged by incrustation and
clean as required.
Control and if necessary clean the smoke duct and the
air intake.
A08
Flue-gas exhaust fan broken
Check that the smoke fan compartment is clean and if it
is dirt that is blocking it.
If insufficient, the smoke fan is defective. Call an
authorized service centre to make the replacement.
A09
The smoke probe is defective and does not
properly measure the temperature of the
discharge smoke
Contact an authorized service centre to replace the
component.
A10
The plug is defective
Contact an authorized service centre to replace the
component.
A11
Defective pellet feeder
Contact an authorized service centre to replace the
component.
A14
Generic failure of sensor
This alarm is not blocked, only a warning screen
appears. Contact an authorized service centre to replace
the component.
A17
Water temperature too high due to:
Stove at maximum power, radiators closed
System oversized e.g. small room, large
capacity stove
This alarm is not blocked, only a warning screen
appears.
Check that all radiators are open. If the alarm persists
contact an authorised service centre.
A18
Water tank temperature too high
This alarm intervenes when the water does not circulate
in the system and therefore the temperature increases.
Check the pump and release it if necessary. If
necessary, contact an authorized service centre to
replace the component.
Service
Periodic maintenance warning
If this flashing messages appears when lighting the
stove, it means that the hours of operation pre-set
before the maintenance have elapsed and a new
maintenance intervention is necessary. Contact a
specialist MCZ technician.
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency