Safety devices – MCZ Club HYDRO 15 kW User Manual
Page 24

PELLET STOVES
Chapter 4
INSTALLATION AND USE MANUAL
page
24
Operation
Technical service - Rights reserved MCZ GROUP S.p.A. - Reproduction prohibited
FRIDAY
at home until 9:00, from 12:00 to 15:00 and from 18:00 on
SATURDAY at home only after 18:00
SUNDAY
at home only after 14:00
Based on these times, from the table in paragraph 4.11.2 the daily
programmes are selected which best suit this routine.
MONDAY
Programme 20
TUESDAY
Programme 43
WEDNESDAY Programme 00
THURSDAY Programme 13
FRIDAY
Programme 34
SATURDAY Programme 10
SUNDAY
Programme 08
To activate this type of customised setting follow the instruction in par.
4.11.2 page 48.
4.17. SAFETY DEVICES
The stove is fitted with the following safety devices:
SMOKE TEMPERATURE SENSOR.
Monitors the temperature of the smoke, and gives permission for
start-up or shuts the stove down when the smoke temperature
falls below the preset value.
PELLET HOPPER TEMPERATURE SENSOR.
If the temperature exceeds the preset safety level, it immediately
shuts down the running of the stove, and has to be reset, after the
stove has cooled, before the it will restart.
BOILER TEMPERATURE PROBE (ALARM A18)
If the temperature of the water approaches shutdown temperature
(95°C) the stove will shut down.
WATER TEMPERATURE PROBE (ALARM A17)
When the water temperature reaches80°C the stove starts to
gradually decrease the power to 85°C. If85 °C is exceeded, a
safety shut down will occur and the stove will re-start when the
stove body has properly cooled.
ELECTRICAL SAFETY
The stove is protected against violent surges of current by the
main fuse, which is located on the control panel at the rear of the
stove. Other fuses to protect the electronic boards are to be found
on the boards themselves.
FAILURE OF THE SMOKE EXTRACTION FAN
If the fan stops, the electronic board shuts off the supply of pellets
in good time, and an alarm is displayed.
BREAKDOWN OF THE REDUCTION MOTOR
If the reduction motor stops, the stove continues to function until it
has cooled down to the minimum level.
- Club HYDRO 15 kW High Efficiency Club HYDRO 15 kW Ver.2009 cod. 7109007 Club HYDRO 22 kW Club HYDRO 22 kW High Efficiency Ego HYDRO Ego HYDRO High Efficieny Musa HYDRO 15 kW Musa HYDRO 15 kW Ver.2009 cod. 7109008 Musa HYDRO 15 kW High Efficiency Musa HYDRO 22 kW Musa HYDRO 22 kW High Efficiency Star HYDRO Star HYDRO High Efficieny Suite HYDRO 15 kW Suite HYDRO 15 kW High Efficiency Suite HYDRO 15 kW Ver. 2009 cod. 7109007 Suite HYDRO 22 kW Suite HYDRO 22 kW High Efficiency