Problems/Causes/Solutions
Technical serivce – Rights reserved MCZ S.p.A. – Reproduction prohibited
PROBLEM
POSSIBLE CAUSES
REMEDY
The smoke
extraction motor
does not work.
1. No electrical supply to the stove.
2. The motor is broken.
3. Defective electronic board.
4. Control panel broken.
1.
Check the supply voltage and the
protection fuse.
2.
Check the motor and capacitor
and replace if necessary.
3.
Replace electronic board.
4.
Replace the control panel.
The convection air
fan runs
continuously.
5.
Temperature sensor defective or
broken.
6.
Fan broken.
5.
Check the operation of the
sensor and replace if necessary.
6.
Check the operation of the
motor and replace if necessary.
Remote control does
not work
7. Remote control batteries flat.
8. Remote control broken.
7. Replace batteries.
8. Replace remote control.
In the automatic
position the stove
always runs at full
power.
9. Room thermostat set to maximum.
10. Temperature sensor defective.
11. Control panel defective or broken.
9.
Reset the thermostat temperature.
10. Check the operation of the
sensor and replace if necessary.
11. Check the panel and replace if
necessary.
The stove does not
run
12. Lack of electricity supply.
13. Pellet sensor in lockout.
14. Fuse blown.
15. Pressure switch broken (lockout
indicated).
16. Smoke outlet or duct blocked.
12. Check that the electric socket is
plugged in and that the main switch
is in position “I”.
13. Clear lockout by resetting the rear
thermostat,
replace the
thermostat if it happens again.
14. Replace the fuse.
15. Replace the pressure switch.
16. Clean the smoke outlet and/or
smoke duct.
ATTENTION !
The operations marked in bold type must be carried
out by specialised MCZ personnel. The manufacturer
refuses to accept any responsibility and the
guarantee lapses if this condition is not respected.