Other alarm signals, Lockout of the stove – MCZ Omega '05 User Manual
Page 41

PELLET STOVE
Chapter 4
INSTALLATION AND USE MANUAL
page
40
Operation
Technical Service – Rights reserved MCZ S.p.A. – Reproduction prohibited
EN
G
L
IS
H
4.10.2.
Other alarm signals
The following table summarizes the messages which may appear on the
display
MESSAGE ON DISPLAY
PANEL
MEANING
OFF
The stove is off
MANUAL
The stove is in manual mode
ON
The stove is on
START
Lighting sequence
P-1 … P-5
Stove operating in manual mode at indicated speed (1,2,3,4 or 5)
ECO-STOP
Stove in automatic mode with "shutdown with temperature"
20°C
Example of room temperature
MON….SUN
Days of the week
DAY
day
HOUR
hour
MINUTE
minutes
ACCESS CODE
access key
SET
setting
CLEANING
Automatic cleaning of the brazier in the set period of time
MCZ SPA
mcz spa
4.10.3.
Lockout of the stove
The following things can cause the stove to lock out:
•
Overheating of the stove body
•
High pressure in the outlet fumes (as read by the pressure
switch) and therefore possible obstruction of the smoke
discharge system or external back-pressure.
The lockout is indicated by the LED (6) lighting up, accompanied by an
audible "beep".
In this situation the shutdown cycle is automatically activated.
Once this process has started, any operation which is an attempt to
reset the system is useless.
The cause of the lockout is shown on the display (8).
WHAT TO DO:
When the stove is cold:
If the message "Alarm hot pel" appears, it will be necessary to
unscrew the cover of the thermostatic sensor fitted to the back of the
stove and press the red button to reset it. Refit the protective cover.
Fig.24-25
If the message "Alarm Press" appears, you need to check if ALL of
the smoke duct, including the combustion chamber, is clean and free of
obstructions. (it is advisable to have this done by a specialized MCZ
technician)
Only after the cause of the blockage has been permanently
eliminated can a fresh attempt to relight the stove be made.
Fig. 25 – How to reset the bulb thermostat once
the stove is cold.
Fig. 24 – Bulb probe reset button