4.10.2.

Other alarm signals

The following table summarizes the messages which may appear on the

display

MESSAGE ON DISPLAY

PANEL

MEANING

OFF

The stove is off

MANUAL

The stove is in manual mode

ON

The stove is on

START

Lighting sequence

P-1 … P-5

Stove operating in manual mode at indicated speed (1,2,3,4 or 5)

ECO-STOP

Stove in automatic mode with "shutdown with temperature"

20°C

Example of room temperature

MON….SUN

Days of the week

DAY

day

HOUR

hour

MINUTE

minutes

ACCESS CODE

access key

SET

setting

CLEANING

Automatic cleaning of the brazier in the set period of time

MCZ SPA

mcz spa

4.10.3.

Lockout of the stove

The following things can cause the stove to lock out:

Overheating of the stove body

High pressure in the outlet fumes (as read by the pressure

switch) and therefore possible obstruction of the smoke

discharge system or external back-pressure.

The lockout is indicated by the LED (6) lighting up, accompanied by an

audible "beep".
In this situation the shutdown cycle is automatically activated.
Once this process has started, any operation which is an attempt to

reset the system is useless.
The cause of the lockout is shown on the display (8).

WHAT TO DO:
When the stove is cold:
If the message "Alarm hot pel" appears, it will be necessary to

unscrew the cover of the thermostatic sensor fitted to the back of the

stove and press the red button to reset it. Refit the protective cover.

Fig.24-25
If the message "Alarm Press" appears, you need to check if ALL of

the smoke duct, including the combustion chamber, is clean and free of

obstructions. (it is advisable to have this done by a specialized MCZ

technician)
Only after the cause of the blockage has been permanently

eliminated can a fresh attempt to relight the stove be made.

Fig. 25 – How to reset the bulb thermostat once

the stove is cold.

Fig. 24 – Bulb probe reset button