Theoretical notes for installation

Technical service – Rights reserved MCZ S.p.A. – Reproduction prohibited

EN
G

L

IS

H

2.7. CONNECTION TO THE FLUE PIPE

The flue pipe must have internal dimensions not greater than 20x20

cm or a diameter of 20 cm; in the case of larger dimensions or poor

operation of the flue pipe (e.g. cracks, poor insulation, etc.) it is

advisable to insert a stainless steel pipe of a suitable diameter all the

way up to the top. Fig.5
Check with suitable instruments that there is a minimum draught of 10

Pa.
At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.
Make a gas-tight connection to the flue pipe, using pipes and

connectors as recommended by us.
It is compulsory to check that an anti-wind chimney has been installed,

in accordance with current standards.

This type of connection ensures the evacuation of the

fumes even in the event of a temporary power cut.

2.8. CONNECTION TO AN EXTERNAL FLUE WITH

INSULATED OR DOUBLE-SKINNED PIPE

The outside flue must have minimum internal dimensions of 10X10 or a

diameter of 10 cm and maximums 20x20 cm or a diameter of 20 cm;
Check with suitable instruments that there is a minimum draught of 10

Pa. Fig.6
The only type of pipe which is permissible is insulated (double-walled)

stainless steel, smooth on the inside, fixed to the wall. Flexible stainless

steel pipe must not be used.
At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.
Make a gas-tight connection to the flue pipe, using pipes and

connectors as recommended by us.
It is compulsory to check that an anti-wind chimney has been installed,

in accordance with current standards.

This type of connection ensures the evacuation of the

fumes even in the event of a temporary power cut.

2.9. CONNECTION TO FLUE PIPE OR SMOKE DUCT

For proper functioning, the connecting pipe between the stove and the

chimney or flue duct must have a slope of not less than 3%. The length

of the horizontal stretch must not exceed 2/3 metres, and the vertical

distance between one tee connector and another (change of direction)

must not be less than 1.5m.
Check with suitable instruments that there is a minimum draught of 10

Pa. Fig.7
At the bottom of the flue pipe, provide an inspection cap to allow

periodic checking and cleaning, which must be done annually.
Make a gas-tight connection to the flue pipe, using pipes and

connectors as recommended by us.

Fig. 5

Fig. 6

Fig. 7

Flue pipe

Anti-wind

chimney

Inspection

0,5 m

Insulted

external

duct

Inspection

0,5 m

3-5 %

2 - 3 m MAX.

M

i

n

i

m

o

1

,

5

-

2

m

t

.

Inspection

0,5 m

Flue pipe

Mi

ni

mum 1,5 – 2 m