On the rear of the stove there is a fuse holding compartment which is
located underneath the supply socket. With a screwdriver open the
cover of the fuse holding compartment, and replace the fuse if
necessary (3.15 AT delayed type). Fig.37
Push the electric plug back in, and press the main switch.
If the problem persists or the fuse blows again, contact an MCZ retailer.
5.3. CHECK OF INTERNAL COMPONENTS
ATTENTION !
Checking of electrical and mechanical components
must be carried out only be qualified personnel with
technical knowledge of combustion and electricity. If
necessary, contact MCZ authorized distributors.
We recommend that an annual maintenance service is carried out,
preferably under a programmed service contract. The essential part of
this service is a visual and functional check on the following
components:
•
Reduction motor
•
Smoke expulsion fan
•
Smoke sensor
•
Heat-exchanger fan
•
Ignition sparkplug
•
Re-settable pellet thermostat
•
Room temperature sensor
•
Pressure switch
•
Main board
•
Silenced board for heat-exchanger
•
Overload fuses for panel - main board - silenced board
•
Wiring
The following is a summary of the checks and/or maintenance tasks
which are indispensable for the correct operation of the stove.
Parts / periods
1 day
2-3 days
30 days
60-90 days
1 year
Burner
●
Perforated deflector
●
Ash drawer
●
Glass
●
Lower exchanger
●
Complete exchanger
●
Smoke ducts
●
Ash drawer door gasket
●
Internal parts
●
Flue pipe
●
Remote control batteries
●
Vano
fusibili
Fuse
compartment