Removing the platen assembly – Epson FX-870/1170 User Manual
Page 89

Disassembly
and Assembly
Removing the Platen Assembly
1.
Remove
the paper guide assembly, ribbon, top cover, front cover, paper eject cover and tractor
unit. (See page
4-5.)
2.
Remove the panel unit. (See page 4-6.)
3.
Remove the upper housing assembly. (See page 4-8.)
4.
Remove the two CBS
screws securing the platen cover.
5.
Disengage the teeth of the platen shaft holders and rotate them. Then slide the left platen
holder to the left.
6.
Remove the platen knob.
7.
Remove the ribbon mask by pushing the two clips.
8.
Slide the platen assembly and remove it.
Platen Knob
CBS
Platen Cover
Platen Shaft Holder
Figure 4-8. Removing the Platen Assembly
4-10
Epson
See also other documents in the category Epson Printers:
- Stylus Pro 7800 (11 pages)
- Stylus Pro 4000 (49 pages)
- Stylus Photo R300 (2 pages)
- Stylus Pro 7000 (147 pages)
- AcuLaser C3000 (316 pages)
- Stylus Pro 7900 (24 pages)
- Stylus Pro 4450 (21 pages)
- 1000 (272 pages)
- T034120 (4 pages)
- T580300 (4 pages)
- 300 (91 pages)
- B 510DN (190 pages)
- B 510DN (218 pages)
- Stylus NX510 (8 pages)
- Stylus Photo RX580 (95 pages)
- T549300 (4 pages)
- B 500DN (168 pages)
- AculaserCX11NF (5 pages)
- 480SXU (24 pages)
- 4500 (317 pages)
- STYLUS RX500 (99 pages)
- 2100 (13 pages)
- Stylus NX215 (2 pages)
- T098320 (4 pages)
- T041020 (4 pages)
- R210 (8 pages)
- All-In-One Stylus Photo RX600 (164 pages)
- 777I (53 pages)
- T033120 (4 pages)
- Stylus CX7000F (8 pages)
- 60 (113 pages)
- T034220 (4 pages)
- WorkForce 40 Series (36 pages)
- T054220 (4 pages)
- Stylus CX3200 (11 pages)
- Stylus CX7800 (18 pages)
- T060220 (4 pages)
- 2500 (180 pages)
- AcuLaser CX11N (4 pages)
- AcuLaser CX11N (32 pages)
- 2000P (16 pages)
- T606600 (4 pages)
- Stylus CX6000 (18 pages)
- FS-4000DN (2 pages)
- MSDS T544700 (4 pages)