Troubleshooting 3

The information in this section can help you identify causes of printer problems and test the
printer to isolate the part that needs to be replaced. The chapter also contains illustrations
showing connector locations and sensor locations. Once you have read this chapter to

determine what tests you need to run on the printer, see Chapter 4 for instructions on how to
disassemble the printer.

WARNING

Before disassembling the printer to perform any troubleshooting tests, disconnect the
power supply cable from the AC power outlet. Failure to do so may cause physical injury.
The power switch is wired in the secondary circuitry. Therefore, the printer’s primary
circuitry remains live even after the power switch is turned off.

When performing the testing described in this chapter, do not connect the printer to the
power source unless instructed to do so in the test. When the power supply must be

connected, use extreme caution, because the voltage may cause physical injury and may

, damage the components of the printer.

Test Points

The test point tables and diagrams have been placed at the

of this chapter to provide you

with

a

quick reference for checking motors, the printhead, printhead drivers, sensors, and the

power supply, if you suspect a problem.

Table 3-1. Power Supply Test Points

Supply

Connector

Pin Numbers

11 and3

Power Supply

Connector

Pin Numbers

1 and3

CN2

Test Method

(Set Meter to Continuity.

Check with Printer Power Off.)

Place one lead on pin 11 and the other on
pin 3 (ground).

Test Method

(Set Meter to Volts.

Check with Printer Power On.)

Place the + lead on pin 1 (5 V) and the

lead on pin 3 (ground).

Place the + lead on pin 9 (35 V) and the

lead on pin 3 (ground).

Meter Reading

Continuity/open means OPERATE is activated
and you can check the power supply voltages.

Meter Reading

v

v

E p s o n