92 2. midi messages transmitted from midi out, Channel voice messages – Edirol V-8 User Manual
Page 92

MIDI Implementation
(continued)
92
2. MIDI messages transmitted from
MIDI OUT
* If MIDI Thru is ON, MIDI messages received at MIDI IN are re-transmitted
without change from MIDI OUT.
* If MIDI Thru is ON, messages from the V-8 itself will not be transmitted.
■
Channel voice messages
●
Control Change
* The messages assigned in MIDI Setup will be transmitted when you operate
the panel. The control changes that can be used are CC#1
–
5, 7
–
31, and
64
–
95. For the factory settings, refer to “Settings Transmitted/Received
❍
Bank Select (controller numbers 0, 32)
Status
2nd byte
3rd byte
BnH
00H
mmH
BnH
20H
llH
mm,ll=bank number: 00 00H - 7F 7FH (bank.1 - bank.16384)
* Sent in combination with Program Change message when an input
selection is made.
* The following controls correspond to each Bank Select message.
--------------------------------------------------------------------------------------------------------
Bank Select
Program No.
Control
MSB | LSB
--------------------------------------------------------------------------------------------------------
50H | 00H (bank.10241)
00H - 07H
MEMORY 1 - 8
--------------------------------------------------------------------------------------------------------
00H | 00H (bank.1)
00H - 07H
Bus A INPUT 1 - 8
--------------------------------------------------------------------------------------------------------
01H | 00H (bank.129)
00H - 07H
Bus B INPUT 1 - 8
--------------------------------------------------------------------------------------------------------
❍
Modulation (controller numbers 1)
Status
2nd byte
3rd byte
BnH
01H
vvH
❍
Breath-type (controller numbers 2)
Status
2nd byte
3rd byte
BnH
02H
vvH
❍
Foot-type (controller numbers 4)
Status
2nd byte
3rd byte
BnH
04H
vvH
❍
Portamento Time (controller numbers 5)
Status
2nd byte
3rd byte
BnH
05H
vvH
❍
Volume (controller numbers 7)
Status
2nd byte
3rd byte
BnH
07H
vvH
❍
Balance (controller numbers 8)
Status
2nd byte
3rd byte
BnH
08H
vvH
❍
Panpot (controller numbers 10)
Status
2nd byte
3rd byte
BnH
0AH
vvH
❍
Expression (controller numbers 11)
Status
2nd byte
3rd byte
BnH
0BH
vvH
❍
Effect Control 1 (controller numbers 12)
Status
2nd byte
3rd byte
BnH
0CH
vvH
❍
Effect Control 2 (controller numbers 13)
Status
2nd byte
3rd byte
BnH
0DH
vvH
❍
General Purpose Controller 1–4 (controller numbers 16–19)
Status
2nd byte
3rd byte
BnH
10H - 13H
vvH
❍
Hold 1 (controller numbers 64)
Status
2nd byte
3rd byte
BnH
40H
xxH
❍
Portamento (controller numbers 65)
Status
2nd byte
3rd byte
BnH
41H
xxH
❍
Sostenuto (controller numbers 66)
Status
2nd byte
3rd byte
BnH
42H
xxH
❍
Soft (controller numbers 67)
Status
2nd byte
3rd byte
BnH
43H
xxH
❍
Legato (controller numbers 68)
Status
2nd byte
3rd byte
BnH
44H
xxH
❍
Hold 2 (controller numbers 69)
Status
2nd byte
3rd byte
BnH
45H
xxH
❍
Sound Controllers1–10 (controller numbers 70–79)
Status
2nd byte
3rd byte
BnH
46 - 4FH
vvH
❍
General Purpose Controllers 5–8 (controller numbers 80–83)
Status
2nd byte
3rd byte
BnH
50 - 53FH
vvH
❍
Portamento Control (controller numbers 84)
Status
2nd byte
3rd byte
BnH
54H
vvH
❍
Effect Depth 2–5 (controller numbers 92–95)
Status
2nd byte
3rd byte
BnH
5C - 5FH
vvH
●
Program Change
Status
2nd byte
CnH
ppH
pp=program number: 00H - 7FH (prog.1 - prog.128)
* Sent in combination with Program Change message when an input
selection is made. For more detailed information refer to the Bank Select
parameters.
●
Channel Pressure
Status
2nd byte
DnH
vvH
* Just as for Control Changes, the messages assigned in MIDI Setup will be
transmitted when you operate the panel. For the factory settings, refer to
“Settings Transmitted/Received Using MIDI” (p. 96).
●
Pitch Bend Change
Status
2nd byte
3rd byte
EnH
llH
mmH
mm, ll = pitch bend value: 00 00H - 40 00H - 7F 7FH (-8192 - 0 - +8191)
* Just as for Control Changes, the messages assigned in MIDI Setup will be
transmitted when you operate the panel. For the factory settings, refer to
“Settings Transmitted/Received Using MIDI” (p. 96).
●
Data Set 1 (DT1)
This is the message that transfers actual data, and is used to specify data for a
device.
Status
Data bytes
Status
F0H
41H, dev, 00H, 00H, 28H, 12H,
F7H
aaH, bbH, ccH, ddH, ..., eeH, sum
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
dev
Device ID (dev: 00H - 1FH, factory setting is 10H)
00H
1st byte of model ID (V-8)
00H
2nd byte of model ID (V-8)
28H
3rd byte of model ID (V-8)
12H
Command ID (DT1)
aaH
Upper byte of address
bbH
Address
ccH
Address
ddH
Data: the actual data to be transmitted. Multi-byte data is
transmitted in the order of the address.
:
:
eeH
Data
sum
Checksum
F7H
EOX (End Of Exclusive)
* For details on setting the address, size, and checksum, refer to “Exclusive
message examples and checksum calculation” (p. 96).
* Data that exceeds 256 bytes must be divided into packets of 256 bytes or
less for transmission. If a subsequent “Data Set 1” message is transmitted,
an interval of at least 20 ms must be left between packets.
V-8_e.book 92 ページ 2010年4月16日 金曜日 午後5時14分