beautypg.com

Specification – Sealey TA203 User Manual

Page 2

background image

Overvoltage Category:. .. . . .. . . .. CAT.111. 1000V.

RS232: . . . .. . . .. . . .. . . .. . . .. . . .. Optically isolated PC interface cable and Windows® 95/98/200/XP compatible software to collect, display, plot and save data.

Display: . . .. . . .. . . .. . . .. . . .. . . .. 4 3.4 digit (4000 counts) LCD display with function and unit sign annunciator.

Analogue Bar Graph: . .. . . .. . . .. 40 segments with measurements 15 times per second.

Polarity: . . .. . . .. . . .. . . .. . . .. . . .. Automatic, (-) negative polarity indication.

Over Range Indication: .. . . .. . . .. “OL” mark indication.

Low Battery Indication: .. . . .. . . .. The is displayed when the battery voltage drops below the operating level.

Auto Power Off: . . .. . . .. . . .. . . .. Meter automatically shuts down after approx. 30 minutes of inactivity.

Measurement Rate: .. . . .. . . .. . . .. 2 times per second, nominal.

Operating Environment: . . .. . . .. 0°C to 50°C (32°F to 122°F) at <70% relative humidity.

Storage Environment: . .. . . .. . . .. -20°C to 60°C (14°F to 140°F) at <80% relative humidity.

Temperature Coefficient: . . .. . . .. 0.2 x (specified accuracy) / °C (< 18°C or > 28°C.

Power: .. . . .. . . .. . . .. . . .. . . .. . . .. Single standard 9 Vollt battery (PP3).

Battery Life: . . .. . . .. . . .. . . .. . . .. 200 hours typical with alkaline battery.

Fuse: . .. . . .. . . .. . . .. . . .. . . .. . . .. 20A/250V, 10.3 x 38mm fast acting ceramic type.

. . .. . . .. . . .. . . .. . . .. . . .. . . .. 0.5A/250V, 5 x 20mm fast acting ceramic type.

Dimensions: . . .. . . .. . . .. . . .. . . .. 197 (H) x 88.4 (W) x 41.2 (D) mm.

Weight Approx: . . . .. . . .. . . .. . . .. 635g including holster.

Accuracy is given at 18°C to 28°C (65°F to 83°F) less than 70% relative humidity.

Range Resolution Accuracy

400.0mV 0.1mV

± 0.5% of reading ± 2 digits

4.000V 1mV

40.00V

10mV

±1.5% of reading ± 2 digits

400.0V 100mV

1000V

1V

± 1.8% of reading ± 2 digits

Range Resolution Accuracy

400.0mV

0.1mV

± 1.5% of reading ± 60 dig

4.000V

1mV

± 1.0% of reading ± 3 digits

40.00V

10mV

± 1.5% of reading ± 3 digits

400.0V 100mV

750V

1V

± 2.0% of reading ± 4 digits

Range Resolution Accuracy

400.0uA

0.1uA

± 1.0% of reading ± 3 digits

4000uA 1uA

40.00mA

10uA

± 1.5% of reading ± 3 digits

400.0mA 100uA

4A

1mA

± 2.5% of reading ± 5 digits

20A 10mA

Range Resolution Accuracy

400.0Ω

0.1Ω

± 1.2% of reading ± 4 digits

4.000kΩ

1Ω

± 1.0% of reading ± 2 digits

40.00kΩ

10Ω

± 1.2% of reading ± 2 digits

400.0kΩ

100Ω

4.000MΩ

1kΩ

40.00MΩ

10kΩ

± 2.0% of reading ± 3 digits

Range Resolution Accuracy

400.0uA

0.1uA

± 1.5% of reading ± 5 digits

4000uA 1uA

40.00mA 10uA

400.0mA 100uA

4A

1mA

± 3.0% of reading ± 7 digits

20A

10mA

± 2.5% of reading ± 7 digits

DC Voltage (Auto Ranging)

AC Voltage (Auto Ranging except 400mV)

Input Impedance: 10MΩ.

Maximum Input 700Vac rms or 1000Vdc.

DC Current (Auto Ranging for uA and mA)

Input Impedance: 10MΩ.

Frequency Range: 50 to 400Hz.

Maximum Input: 750Vac rms or 100Vdc.

Overload Protection: 0.5A/250V and 20A/250V Fuse.

Maximum Input:400mAac rms or 400mAdc on uA/mA ranges

20A ac rms or dc on 10A range.

AC Current (Auto Ranging for uA and mA

Overload Protection: 0.5A/250V and 20A/250V Fuse.

Frequency Range:50 to 400Hz

Maximum Input: 40mA ac rms or 400mA dc on uA/mA ranges,

20A ac rms or dc on 20A range.

Resistance (Auto Ranging)

Range Resolution Accuracy

40.00nF

10pF

± 5.0% of reading ± 7 digits

400.0nF 0.1nF

4.000uF

1nF

± 3.0% of reading ± 5 digits

40.00uF 10nF

100.0uF

0.1uF

± 5.0% of reading ± 5 digits

Capacitance (Auto Ranging)

Input Protection: 250Vac rms or 250Vdc.

Input Protection: 250Vac rms or 250Vdc.

Range Resolution Accuracy

5Hz 0.001Hz

50Hz

0.01Hz

± 1.5% of reading ± 5 digits

500Hz 0.1Hz

5kHz 1Hz

30.00kHz

10Hz

± 1.2% of reading ± 3 digits

Frequency (Auto Ranging)

Sensitivity: >5V RMS MIN.

Overload Protection: 250Vac rms or dc.

Range Resolution Accuracy

0.1%~99.9%

0.1%

± 1.2% of reading ± 4 digits

Duty Cycle (Auto Ranging)

Pulse Width: >100us, <100ms

Sensitivity: < 0.5V rms

Overload Protection: 250Vac rms or dc.

Range Resolution Accuracy

2.0~10.0ms

0.1ms

± 3% of reading ± 10 digits

Pulse Width

Overload Protection: 250Vac rms or dc.

Range Resolution Accuracy

-20°C~+760°C 1°C

± 3.0% of reading ± 5 digits

-4°F~+1400°F 1°F

(Meter only, probe accuracy

not included).

Range

Resolution Accuracy

RPM 4 600~4000RPM

1RPM

600~1200RPM

10RPM

(X 10PM)

±2% of rdg ± 4 digits

RPM 2 300~4000 RPM

1RPM

300~600RPM 10RPM

(x 10RPM)

Temperature

Sensor: Type K Thermocouple

Range Resolution Accuracy

0.3mA typical 1mV

± 10% of reading ±5 digits

Diode test

Open Circuit Voltage: 1.5Vdc typical

Overload Protection: 250Vac rms or dc.

Cylinder Range Resolution Accuracy

1CYL 0~360.0°

2CYL 0~180.0°

3CYL 0~120.0°

4CYL 0~90.0°

5CYL

0~72.0° 0.1°

± 2.0% of reading ± 4 digits

6CYL 0~60.0°

8CYL 0~45.0°

10CYL 0~36.0°

12CYL 0~30.0°

Dwell Angle

Overload Protection: 250Vac rms or dc.

Effect Reading: >600RPM

Overload Protection: 250Vac rms or dc.

RPM (Tach)

Audible Continuity

Audible threshold:

Less than 150Ω

Test Current:

<0.3mA

Overload Protection: 250Vac rms or dc.

3. SPECIFICATION

Original Language Version

© Jack Sealey Limited

TA203.V2 Issue No: 3(L)- 17/06/14