Common symbology properties – Casio Naurtech CETerm Ver.5.5 Scripting Guide User Manual
Page 134

C
OMMON
S
YMBOLOGY
P
ROPERTIES
Symbology properties are unique for each session. Symbology properties begin
with “sessionX.scanner.SSS” where X is 1 through 4 and SSS represents a
symbology name and may be 3 or more characters long. For example
“session4.scanner.upca.enabled”. If no „X‟ value is found, the currently active
session number is used. See the Symbology Names table below for SSS values.
NOTE: If you are changing the scanner properties for the currently activesession,
you must call CETerm.PostIDA( “IDA_SCAN_APPLYCONFIG”, 0 ); for
the changes to take effect.
WARNING: Not all properties are applicable to all hardware devices or all
symbologies. Different devices may use different names to refer to the
same parameters. You should look at the settings available in the
CETerm configuration dialogs to determine if the property is
appropriate and what values it may accept. This is also true for the
symbologies that a device supports. You may be able to successfully
change a parameter that is not supported on a device.
Last Property Level
Description
enabled
Symbology is enabled. T/F
verifycheck
Require check digit validation. T/F
redundancy
Scan redundancy flag. T/F (Symbol)
reportcheck
Report the check digit with the data. T/F
reportnumbersystem
Report UPC number system. T/F
reportcountry
Report UPC country code. T/F
reportstartstop
Report start/stop digits with barcode data. T/F
converttoupca
Convert barcode output to UPCA. T/F
converttoean13
Convert barcode output to EAN-13. T/F
supplemental2
Enable 2 digit supplemental or add-on barcode. T/F
supplemental5
Enable 5 digit supplemental or add-on barcode. T/F
supplementalrequired
Require supplemental on UPC. T/F
supplementalseparator
Insert supplemental separator. T/F
addendum
Supplemental mode. none, optional, required
minlength
Minimum barcode length. Not supported by all
symbologies. See configuration dialogs for ranges.
maxlength
Maximum barcode length. Not supported by all
symbologies. See configuration dialogs for ranges.
stripleading
Strip characters from start of barcode. 0-32
striptrailing
Strip characters from end of barcode. 0-32
customid
Custom symbology ID. 4 character string