TI Model 880 Printer Emulation 4-14
The following table provides a complete list of Model 880 error codes.
Model 880 Error Codes
Code
Description
02
ROM error
03
NVRAM error
04
UART error
06
Communication controller error
07
Standard RAM error
12
Paper-out condition
23
Receive buffer overflow condition
24
Parity error
29
Invalid escape sequence
2A
Escape sequence not executed
2B
Form length error
2C
Character set not installed
Select Unidirectional Printing
Escape sequence:
ESC
u
Hexadecimal:
1B
75
This command causes the printer to print subsequent characters from
left to right only.
Cancel Unidirectional Printing
Escape sequence:
ESC
b
Hexadecimal:
1B
62
This command cancels the unidirectional print mode and causes the
printer to resume bidirectional (normal) printing.
Form Format Selection Commands
The form format commands let you select and set some form-related
parameters.
Set Form Length to
N Lines
Escape sequence:
ESC
[
N
t
Hexadecimal:
1B
5B
N
74
The variable N can be any value in the range of 0 through 113
(hexadecimal 00 through 31 31 33).