Chapter 4, Bios settings – Lanner FX-3210 User Manual

Page 34

background image

29

Bios Settings

Chapter 4

Network Application Platforms

PC Health Status

This menu shows the hardware monitor configuration

settings. Select an item then press to display the

configuration options.

SYSIN/CPUIN/AUXIN Temperature

The onboard hardware monitor automatically detects and

displays the CPU and motherboard temperatures.

FAN1/FAN2/FAN3/FAN4 Speed

The onboard hardware monitor automatically detects

and displays the CPU , chassis and system fan speeds in

rotations per minute (RPM). If the fan is not connected to

the motherboard, it displays N/A.

CPU Voltage, 3.3V voltage, 5V voltage, 12V voltage

The onboard hardware monitor automatically detects the

voltage output through the onboard voltage regulators.

Smart Fan Mode Configuration

It allows you to configure the smart fan feature. You

can manually turn on the CPU fan or set the target CPU

temperature at which the CPU fan will start running if the

fan is not yet turned on. And the CPU fan can also be turned

off automatically if the temperature for the CPU is at or

below the specified value. Refer to Motherboard Layout on

Chapter 3 Block Diagram for CPU fan connectors.

Item

Selection

Manual

Mode

Manually set the fan speed

Smart Fan

Control

set the target system temperature at which

the system fan will start running if the fan is

not yet turned on with this mode. And the

system fan can also be turned off automati-

cally if the temperature for the system is at

or below the specified value.

FCTRL5/FCTRL6 FAN Mode

The FCTRL5 is for setting the parameters for FAN2 and

FAN4 for CPU fans.
The FCTRL6 is for setting the parameter for FAN1 and FAN3

for Auxiliary fans.