Option high priority alarm codes – Yaskawa V1000-Series Option SI-EP3/V PROFINET User Manual
Page 50

11 Communication
50
YASKAWA SIEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Technical Manual
Option High Priority Alarm Codes
These codes are transmitted as Manufacturer Specific Diagnostic high priority alarms that can be seen in the PLC
configuration software. These high priority codes are the same codes that appear in the drive manual, except with an
offset of 0400 (hex).
Table 28 PROFINET Option High Priority Alarm Codes
Drive Alarm
Code
(hex)
Description
Corrective Action
1000
None
-
1001
DC Bus Fuse Open (PUF)
Output Transistor Failure. Replace the drive
1002
DC Bus Undervolt (Uv1)
Input power fluctuation too large
1003
CTL PS Undervolt (Uv2)
Cycle drive power and replace drive if fault continues
1004
MC Answerback (Uv3)
Cycle drive power and replace drive if fault continues
1005
Short Circuit (SC)
Check drive wiring
Cycle drive power and replace drive if fault continues.
1006
Ground Fault (GF)
Check for motor and/or cable damage
1007
Over Current (oC)
Check motor, motor load and accel/decel rates
1008
DC Bus Overvolt (oV)
Check incoming voltage
Check deceleration time
1009
Heatsink Overtemp (oH)
Check ambient temperature
Check drive cooling fan
100A
Heatsink Max Temp (oH1)
Check drive cooling fan
100B
Motor Overload (oL1)
Check the load, accel/decel and cycle times
Check motor rated current (E2-01)
100C
Inv Overload (oL2)
Check the load, accel/decel and cycle times
Check drive rating
100D
Overtorque Det 1 (oL3)
Check L6-02 and L6-03 settings
Check system mechanics
100E
Overtorque Det 2 (oL4)
Check L6-05 and L6-06 settings
Check system mechanics
100F
DynBrk Transistor (rr)
Cycle drive power and replace drive if fault continues
1010
DynBrk Resistor (rH)
Check load, operating speed and deceleration time
1011
External Fault 3 (EF3)
Multifunction digital input set to external fault
Circuit at terminal is closed
1012
External Fault 4 (EF4)
1013
External Fault 5 (EF5)
1014
External Fault 6 (EF6)
1015
External Fault 7 (EF7)
1016
External Fault 8 (EF8)
1017
Heatsink Fan (FAn)
Check drive cooling fan
1018
Overspeed Det (oS)
Check reference and reference gain
Check F1-08 and F1-09 settings
1019
Speed Deviation (dEV)
Check load, accel/decel times and system mechanics
Check F1-10 and F1-11 settings
101A
PG Open (PGo)
Check PG card connections
101B
Input Phase Loss (PF)
Excessive input voltage fluctuation
101C
Output Phase Loss (LF)
Check for broken wire/loose terminals
Check motor rating
101D
None
-
101E
Operator Disconnected (oPr)
Reconnect the digital operator
101F
EEPROM R/W Error (Err)
Cycle drive power and replace drive if fault continues
1020
None
-