Prior to installing the option, Choosing the correct installation procedure – Yaskawa V1000-Series Option SI-EP3/V PROFINET User Manual
Page 14

5 Installation Preparation
14
YASKAWA SIEP YEACOM 06A V1000 Option PROFINET SI-EP3/V Technical Manual
Prior to Installing the Option
Prior to installing the option, wire the drive, make necessary connections to the drive terminals, and verify that the drive
functions normally without the option installed. Refer to the product manual packaged with the drive for information on
wiring and connecting the drive.
Choosing the Correct Installation Procedure
The installation procedure differs between NEMA 4X and IP00/IP20 enclosure types. The enclosure type is identified
within the drive model number. Refer to STEP
on page
to identify the drive enclosure type.
1.
Locate the drive model number using
and
. Record the model number for use in STEP
Figure 4
Figure 4 Model Number Location: IP00/IP20 Open Chassis and IP20/NEMA Type 1 Enclosure
Figure 5
Figure 5 Model Number Location: NEMA 4X Enclosures
2.
Use
to find the digit within the model number that identifies the enclosure type. Record the enclosure
type for use in STEP
Do not use unshielded cable for control wiring.
Failure to comply may cause electrical interference resulting in poor system performance.
Use shielded twisted-pair wires and ground the shield to the ground terminal of the drive.
Properly connect all pins and connectors.
Failure to comply may prevent proper operation and possibly damage equipment.
Check wiring to ensure that all connections are correct after installing the option and connecting any other
devices.
Failure to comply may result in damage to the option.
NOTICE
Model Number
Location
CIMR-VUBA00012GAA
200V 1PHASE 12 0A/11.0A S/N J013ZB797110004
Model Number
Location