3.0 I/O Definitions of Terminals 1 and 2

Terminal 1 Move Positive

Ths terminal is used run a motion command or jog function in the positive
direction. See command chart above.

Terminal 2 Move Negative

Ths terminal is used run a motion command or jog function in the negative
direction. Motion destination are inverted when this command is given. See
command chart above.


3.1 I/O Definitions of multi-function inputs

For constants H1-01 through H1-06.

Setting Display

Description

3

Multi-Step Ref 1

The binary combination of multi-step inputs 1-5 will select move profiles
1-31. Each profile consists of a speed reference from D1-01~08, a length
from A2-01~31, and accel / decel times from C1-01~08. See command
chart above.

4

Multi-Step Ref 2

See setting 3 above

5

Multi-Step Ref 3

See setting 3 above

86

Multi-Step Ref 4

See setting 3 above

87

Multi-Step Ref 5

See setting 3 above

80 Enable

Enable inverter: Open = stop, Closed = run.
Enables the drive to output power to the motor. No move, home, or jog
commands will be accepted without this input.

81

Home Switch

Home limit switch input: The home limit polarity (NO or NC) is set in
parameter P1-04.

82

Home Command

Home command: Open = no action, Closed = Run homing.
This input will initiate the homing routine set up in the P1 and P2
parameters. Note: Drive must also be enabled.

84

Positive OT Limit

Switch

Positive over travel limit switch: The OT limit polarity (NO or NC) is set in
parameter P1-04. Jogging in the negative direction can move the
machine off this limit switch.

85

Negative OT Limit

Switch

Positive over travel limit switch: The OT limit polarity (NO or NC) is set in
parameter P1-04. Jogging in the positive direction can move the machine
off this limit switch.



3.3 Multi-Step Digital Input when DI-08 option card is used

Because there is a limited number on inputs on the controller, it is possible to run out if attempting to use all 31 multi-step
profiles. If the DI-08 option card is installed in the controller, the five multi-step input will come from the first five inputs on
the DI-08 card.