beautypg.com

Motion control, Homing type home neg w/bu, 2 p2 group parameters – Yaskawa G5 Motion Control User Manual

Page 13

background image

Motion Control

Date: 08/18/04, Rev: 04-08

Page 13 of 22

TM.G5SW.020


4.2 P2 Group Parameters





P2-01 Homing Type

Tells the controller the action o take when a home command is issued.

Setting Function

Description

0 Home

Negative

Homing direction is negative and occurs on the leading edge of the homing
switch.

1

Home Negative w/

Backup

Homing direction is negative, when machine get to leading edge of the homing
switch it will travel positive to get off the switch and then approach the switch at
a very slow speed to find the leading edge.

2 Home

Positive

Homing direction is positive and occurs on the leading edge of the homing
switch.

3

Home Positive w/

Backup

Homing direction is positive, when machine get to leading edge of the homing
switch it will travel negative to get off the switch and then approach the switch at
a very slow speed to find the leading edge.

4

Home Negative w/

marker

Homing direction is negative and occurs at the first marker pulse after the
leading edge of the homing switch.

5

Home Positive w/

marker

Homing direction is positive and occurs at the first marker pulse after the leading
edge of the homing switch.






P2-02 Homing Speed


This parameter is the speed reference used for course homing.





P2-03 Homing Back Up Speed


This parameter is the speed reference used for the back up portion of the homing routine.

Setting Range:

0 to 5

Factory Default:

1

Modbus Address:

0590 Hex

Homing Type

Home Neg w/BU

Setting Range:

0.00 to 400.00 Hz

Factory Default:

10.00 Hz

Modbus Address:

0591 Hex

Homing Speed

P2-02 = 10.00 Hz

Setting Range:

0.00 to 400.00 Hz

Factory Default:

2.00 Hz

Modbus Address:

0592 Hex

Homing BU Speed

P2-03 = 2.00 Hz