12 technical data – SMA VIEW-10 User Manual
Page 46

12 Technical Data
SMA Solar Technology AG / SMA America, LLC
46
SunnyView-BA-en-13
User Manual
12 Technical Data
Mechanical Data
Width x height x depth without tabletop stand
151.9 mm x 109 mm x 23.5 mm
(5.98 in. x 4.29 in. x 0.93 in.)
Width x height x depth with tabletop stand
151.9 mm x 109 mm x 25.5 mm
(5.98 in. x 4.29 in. x 1 in.)
Weight without tabletop stand
245 g
(8.64 oz.)
Weight with tabletop stand
293 g
(10.34 oz.)
Certified countries
Australia, Belgium, Denmark, Germany, France,
Greece, Great Britain, Italy, Japan, Canada,
Austria, Switzerland, USA
Voltage Supply
Voltage supply
Plug-in power supply
Input voltage
90 V
AC
to 240 V
AC
, 50 Hz/ 60 Hz
Typical power consumption
3.75 W
Maximum power consumption
8 W
Maximum current consumption
1.6 A
Ambient Conditions
Ambient temperature
0°C to +40°C
(+32°F to +104°F)
Humidity, non-condensing
5% to 95%
Degree of protection* / NEMA class
* Degree of protection as per IEC 60529
IP20 / NEMA 1
Mounting location
Indoors
Communication
Inverter communication
Bluetooth Wireless Technology Class 1
Maximum number of inverters
12
Maximum number of devices - SMA CT Meter
1
Maximum range in free-field conditions
100 m (328 ft.)