9  Technical Data

SMA Solar Technology AG

32

SCCP-JP-MA-Silence-en-10

Mounting Instructions

Efficiency*

Protective Devices

General Data

* Efficiency measured without internal power supply

Max. efficiency / European efficiency /

CEC weighted efficiency

98.6% / 98.4% / 98.5%

Input-side disconnection point

Motor-driven DC load-break switch

AC disconnect device

AC circuit breaker

DC overvoltage protection

Surge arrester type I

Lightning protection (according to IEC 62305-1)

Lightning protection level III

Grid monitoring

Islanding detection

active

Ground fault monitoring / remote ground fault monitoring

○ / ○

Insulation monitoring

Surge arrester for communication interface/

string current monitoring

○ / ○

Surge arrester for auxiliary power supply

Surge arrester type I and type II

Protection class (according to IEC 62103) /

overvoltage category (according to IEC 60664-1)

I / III

Dimensions (width x height x depth)

2,562 mm / 2,272 mm / 1,210 mm

Weight*

* With mounted sound absorber

approx. 1,850 kg

Operating temperature range

-25°C to +62°C

Noise emission**

** Sound pressure level at a distance of 10 m with mounted sound absorber

54 db(A)

Max. self-consumption (operation)*** /

self-consumption (night)

*** Self-consumption during rated operation

1,900 W / < 100 W

External auxiliary supply voltage

230 / 400 V (3/N/PE)

Cooling concept

OptiCool

Degree of protection: electronics /

connection area (as per IEC 60529)

IP54 / IP43

Application

In unprotected outdoor environments

Maximum permissible value for relative humidity

(non-condensing)

15% to 95%

Maximum operating altitude above MSL

2,000 m

Fresh air consumption

3,000 m³/h