beautypg.com

5 mounting the kick plate for the sound absorber, 6 mounting the ventilation plate, 7 mounting the kick plates – SMA SC 500CP-10-JP Mounting Instructions User Manual

Page 19: 8 mounting the silencing baffle

background image

SMA Solar Technology AG

6  Assembly

Mounting Instructions

SCCP-JP-MA-Silence-en-10

19

6.5 Mounting the Kick Plate for the Sound Absorber

1. Apply metal-free allround paste to all threads in the base area.
2. Position and align the kick plate for the sound absorber on the

enclosure.

3. Screw pan head flange screws into the threads.
4. Tighten the pan head flange screws on the kick plate with a suitable screwdriver (torque: 8 Nm)

6.6 Mounting the Ventilation Plate

The guide rails for the ventilation plate are located in the floor area of the inverter cabinet.

Procedure:

• Slide the ventilation plate into the guide rails in the inverter cabinet from the front. The ventilation grid in the

ventilation plate should be facing the rear panel.

☑ The ventilation plate is flush with the Sunny Central.

✖ The ventilation plate will not go all the way in?

• Grip the ventilation plate from underneath and press the middle part upwards while sliding it in.

6.7 Mounting the Kick Plates

1. Position and align the kick plates with soundproofing material on the enclosure.
2. Screw the previously retained pan head flange screws into the threads.
3. Tighten the pan head flange screws on the kick plate with a suitable screwdriver (torque: 8 Nm)

6.8 Mounting the Silencing Baffle

Procedure:
To mount the silencing baffle, perform the following actions in the specified order. The exact procedure is described in

the steps below.

• Mounting the rear panel of the silencing baffle
• Mounting the lid of the silencing baffle
• Mounting the rain protection

Mounting the Rear Panel of the Silencing Baffle

Required mounting material:

☐ 2 cylinder head screws
☐ 2 contact washers