beautypg.com

Interfaces position values – HEIDENHAIN Length Gauges User Manual

Page 45

background image

45

Pin layout

8-pin coupling,

M12

15-pin
D-sub connector,
male
For IK 215/PWM 20

Voltage supply

Absolute position values

8

2

5

1

3

4

7

6

4

12

2

10

5

13

8

15

U

P

Sensor

U

P

0 V

Sensor

0 V

DATA

DATA

CLOCK

CLOCK

Brown/Green

Blue

White/Green

White

Gray

Pink

Violet

Yellow

Interfaces
Position values

The EnDat interface is a digital,

bidirectional

interface for encoders. It is

capable both of transmitting position

values

as well as transmitting or updating

information stored in the encoder, or saving

new information. Thanks to the serial

transmission method

, only four signal

lines

are required. The DATA data is

transmitted in synchronism with the

CLOCK signal from the subsequent

electronics. The type of transmission

(position values, parameters, diagnostics,

etc.) is selected through mode commands

that the subsequent electronics send to

the encoder. Some functions are available

only with EnDat 2.2 mode commands.

Ordering designation

Command set

Incremental signals

EnDat01

EnDat 2.1 or

EnDat 2.2

With

EnDat21

Without

EnDat02

EnDat 2.2

With

EnDat22

EnDat 2.2

Without

Versions of the EnDat interface

Absolute encoder

Subsequent electronics

» 1 V

PP

A*)

» 1 V

PP

B*)

Operating

parameters

Operating

status

Parameters

of the OEM

Parameters of the encoder

manufacturer for

EnDat 2.1

EnDat 2.2

*)

Depends on

encoder

Absolute

position value

EnDat interf

ace

Incremental

signals *)

The Interfaces of HEIDENHAIN

Encoders brochure, ID 1078628-xx,

includes comprehensive descriptions of

all available interfaces as well as general

electrical information.