HEIDENHAIN Length Gauges User Manual
Page 41

41
Functions
Input
Interpolation or
subdivision
Output
Model
Interface
Qty.
Interface
ND 200
Evaluation unit for
• Measurement equipment
• Adjustment and inspection equipment
• SPC inspection stations
–
» 1 V
PP
» 11 µA
PP
EnDat
1
4096-fold
RS-232-C/V-24
USB
Ethernet
1)
ND 280
• Metrological and statistical functions (sorting and
tolerance checking, measurement series, SPC)
• Second encoder
1)
for sum/difference display,
temperature compensation
Up to 2
ND 287
ND 1100 QUADRA-CHEK
Evaluation electronics for
• Positioning equipment
• Measuring fixtures
• Measurement series with min./max. value storage
• Connection for touch probe
» 1 V
PP
« TTL
2
10-fold (at 1 V
PP
)
RS-232-C/V-24
USB
ND 1102
3
ND 1103
4
ND 1104
ND 2100 G GAGE-CHEK
Evaluation electronics for
• Multipoint inspection apparatuses
• SPC inspection stations
• Programming of up to 100 parts
• Graphic display of measurement results
• Sorting and tolerance checking using tolerance and
warning limits
• Measurement series with min./max. value storage
• Entry of formulas and combinations
• Functions for statistical process control (SPC)
» 1 V
PP
« TTL
EnDat
4
10-fold (at 1 V
PP
)
RS-232-C/V-24
USB
ND 2104 G
8
ND 2108 G
MSE 1000
Modular evaluation electronics for
• Multipoint inspection apparatuses
• SPC inspection stations
• Modular design
• Configurable as desired
• Various interfaces
• Fast communication with higher-level computer
system
• Universal outputs
» 1 V
PP
« TTL
EnDat
Analog
LVDT
HBT
Up to 250 4096-fold
Ethernet
MSE 1000
EIB 700
Evaluation electronics for
• Testing stations
• Multipoint inspection apparatuses
• Mobile data acquisition
• Precise position measurement up to 50 kHz
updating rate
• Programmable measured-value inputs
• Internal and external measured-value triggers
• Measured-value memory for approx. 250 000
measured values per channel
• Connection over standard Ethernet interface to
higher-level computer systems
» 1 V
PP
4
4096-fold
Ethernet
EIB 741
EIB 742
IK 220
Evaluation electronics for installation in
computer systems with PCI interface for
• Measuring and testing stations
• Programmable measured-value inputs
• Internal and external measured-value triggers
• Measured-value memory for 8192 measured
values per channel
• Optional assemblies for encoder outputs and
external inputs/outputs
» 1 V
PP
» 11 µA
PP
EnDat
SSI
2
4096-fold
PCI bus
IK 220
1)
Optional for ND 287