beautypg.com

2 measure (cycle 3), Cycle run, Please note while programming – HEIDENHAIN TNC 640 (34059x-04) Cycle programming User Manual

Page 533: Measure (cycle 3), Measure (cycle 3) 18.2

background image

MEASURE (Cycle 3) 18.2

18

TNC 640 | User's Manual Cycle Programming | 3/2014

533

18.2

MEASURE (Cycle 3)

Cycle run

Touch Probe Cycle 3 measures any position on the workpiece
in a selectable direction. Unlike other measuring cycles, Cycle 3
enables you to enter the measuring range

SET UP and feed rate

F directly. Also, the touch probe retracts by a definable value after
determining the measured value

MB.

1 The touch probe moves from the current position at the entered

feed rate in the defined probing direction. The probing direction
must be defined in the cycle as a polar angle.

2 After the TNC has saved the position, the touch probe stops.

The TNC saves the X, Y, Z coordinates of the probe-tip center in
three successive Q parameters. The TNC does not conduct any
length or radius compensations. You define the number of the
first result parameter in the cycle.

3 Finally, the TNC moves the touch probe back by that value

against the probing direction that you defined in the parameter
MB.

Please note while programming:

The exact behavior of Touch Probe Cycle 3 is
defined by your machine tool builder or a software
manufacturer who uses it within specific touch probe
cycles.

The

DIST (maximum traverse to touch point) and F

(probing feed rate) data from the touch-probe table,
which are effective in other measuring cycles, do not
apply in Touch Probe Cycle 3.

Remember that the TNC always writes to four
successive Q-parameters.

If the TNC was not able to determine a valid touch
point, the program is run without error message. In
this case the TNC assigns the value –1 to the 4th
result parameter so that you can deal with the error
yourself.

The TNC retracts the touch probe by no more than
the retraction distance

MB and does not pass the

starting point of the measurement. This rules out any
collision during retraction.

With function

FN17: SYSWRITE ID 990 NR 6 you can

set whether the cycle runs through the probe input
X12 or X13.