ROTATION (Cycle 10, DIN/ISO: G73) 11.6

11

TNC 640 | User's Manual Cycle Programming | 3/2014

269

Please note while programming:

An active radius compensation is canceled
by defining Cycle 10 and must therefore be
reprogrammed, if necessary.

After defining Cycle 10, you must move both axes of
the working plane to activate rotation for all axes.

Cycle parameters

Rotation: Enter the rotation angle in degrees (°).
Input range –360.000° to +360.000° (absolute or
incremental)

NC blocks

12 CALL LBL 1
13 CYCL DEF 7.0 DATUM SHIFT
14 CYCL DEF 7.1 X+60
15 CYCL DEF 7.2 Y+40
16 CYCL DEF 10.0 ROTATION
17 CYCL DEF 10.1 ROT+35
18 CALL LBL 1