MEASURE COORDINATE (Cycle 427, DIN/ISO: G427, software option

17)

15.11

15

TNC 620 | User's Manual Cycle Programming | 2/2015

407

15.11

MEASURE COORDINATE (Cycle 427,
DIN/ISO: G427, software option 17)

Cycle run

Touch Probe Cycle 427 finds a coordinate in a selectable axis
and saves the value in a system parameter. If you define the
corresponding tolerance values in the cycle, the TNC makes a
nominal-to-actual value comparison and saves the deviation value in
system parameters.

1 Following the positioning logic, the TNC positions the touch

probe at rapid traverse (value from

FMAX column) (see

"Executing touch probe cycles", page 298) to touch point

1

.

The TNC offsets the touch probe by the safety clearance in the
direction opposite to the defined traverse direction.

2 Then the TNC positions the touch probe to the entered touch

point

1

in the working plane and measures the actual value in

the selected axis.

3 Finally the TNC returns the touch probe to the clearance

height and saves the measured coordinate in the following Q
parameter.

Parameter number

Meaning

Q160

Measured coordinate

Please note while programming:

Before a cycle definition you must have programmed
a tool call to define the touch probe axis.