Touch Probe Cycles: Automatic Measurement of Workpiece Misalignment

13.7 Compensating workpiece misalignment by rotating the C axis

(Cycle 405, DIN/ISO: G405, software option 17)

13

320

TNC 620 | User's Manual Cycle Programming | 2/2015

Set to zero after alignment Q337: definition of
whether the TNC should set the display of the C-
axis to zero, or write the angular misalignment in
column C of the datum table:

0

: Set the display of the C-axis to zero

>0

: Write the measured angular misalignment

with correct algebraic signs in the datum table.
Line number = value of Q337. If a C-axis shift is
registered in the datum table, the TNC adds the
measured angular misalignment.