beautypg.com

HEIDENHAIN TNC 620 (81760x-02) Cycle programming User Manual

Page 309

background image

BASIC ROTATION over two holes (Cycle 401, DIN/ISO: G401,

software option 17)

13.3

13

TNC 620 | User's Manual Cycle Programming | 2/2015

309

Compensation Q402: Define whether the TNC
should set the measured misalignment as basic
rotation or should align via rotating the rotary table:

0

: Set basic rotation

1

: Rotate the rotary table

If you specify rotating the rotary table, the TNC
does not save the measured misalignment, even if
you have defined a table row in parameter

Q305.

Set to zero after alignment Q337: Define whether
the TNC should set the angle of the aligned rotary
axis to 0 in the preset table or in the datum table
after the alignment:

0

: Do not set the angle of the rotary axis to 0 in the

table after alignment

1

: Set the angle of the rotary axis to 0 in the table

after alignment. The TNC sets the display to 0 only if
you have defined

Q402=1.