Touch Probe Cycles: Automatic Datum Setting

14.13 DATUM IN ONE AXIS (Cycle 419, DIN/ISO: G419, software option

17)

14

370

TNC 620 | User's Manual Cycle Programming | 2/2015

14.13

DATUM IN ONE AXIS (Cycle 419,
DIN/ISO: G419, software option 17)

Cycle run

Touch Probe Cycle 419 measures any coordinate in any axis
and defines it as datum. If desired, the TNC can also enter the
measured coordinate in a datum table or preset table.

1 Following the positioning logic, the TNC positions the touch

probe at rapid traverse (value from

FMAX column) (see

"Executing touch probe cycles", page 298) to the programmed
touch point

1

. The TNC offsets the touch probe by the safety

clearance in the direction opposite the programmed probing
direction.

2 Then the touch probe moves to the programmed measuring

height and measures the actual position with a simple probing
movement.

3 Finally the TNC returns the touch probe to the clearance height

and processes the determined datum depending on the cycle
parameters Q303 and Q305 (see "Characteristics common to all
touch probe cycles for datum setting", page 326
).

Please note while programming:

Before a cycle definition you must have programmed
a tool call to define the touch probe axis.

If you use Cycle 419 several times in succession to
save the datum in more than one axis in the preset
table, you must activate the preset number last
written to by Cycle 419 after every execution of Cycle
419 (this is not required if you overwrite the active
preset).