beautypg.com

Fn 19: plc: transfer values to the plc, 8 a d ditional f unctions – HEIDENHAIN TNC 620 (340 56x-02) User Manual

Page 254

background image

254

Programming: Q Parameters

8.8 A

d

ditional F

unctions

Example: Assign the value of the active scaling factor for the
Z axis to Q25

FN 19: PLC: Transfer values to the PLC

The function FN 19: PLC transfers up to two numerical values or
Q parameters to the PLC.

Increments and units: 0.1 µm or 0.0001°

Example: Transfer the numerical value 10 (which means 1 µm or
0.001°) to the PLC

Touch probe cycles, 990

1

-

Approach behavior:
0 = standard behavior
1 = effective radius, set-up clearance is zero

2

-

0 = probe monitoring off
1 = probe monitoring on

Execution status, 992

10

-

Block scan active
1 = yes, 0 = no

11

-

Search phase

14

-

Number of the last FN14 error

16

-

Real execution active
1 = execution , 2 = simulation

Group name, ID number

Number

Index

Meaning

55 FN 18: SYSREAD Q25 = ID210 NR4 IDX3

56 FN 19: PLC=+10/+Q3