Output Format of the Compensation-Value Table
Line: Start
Each compensation-value output begins with the start character < * > ( HEX: 0x2A)
*
3 characters
Line: Counter model designation
Output of model designation and unit of measure
N D - 2 8 1 B M M
13 characters 5 characters 2 characters
Model display unit, left-aligned Unit of meas. End of line
Line: Compensation value 0
Output of compensation-value no. 0
C M P . N R . 0 0 = + 0 . 0 0 0 0
13 characters 3 char. 13 characters 2 characters
Compensation-value no., left-aligned Sep. block Compensation value, right-aligned End of line
Output of compensation values 1 - 63
Output of compensation values
C M P . N R . 6 3 = + 0 . 0 1 2 3
13 characters 3 char. 13 characters 2 characters
Compensation-value no., left-aligned Sep. block Compensation-value, right-aligned End of line
Last line:
Each compensation-value table ends with the final character <*> (HEX: 0x2A)
*
3 characters
Output Format of the Compensation-Value Table