Technical data – Grass Valley RSE1 User Manual
Page 8

RSE 1
Stand-Alone Controller
3
Rev. 1 / 02.2002
2.
TECHNICAL DATA
Mechanics
19” Rackframe
Width: 482 mm (19”)
Depth: 251 mm (9.9”)
Height: 43mm (1.7”)
Weight: approx. 7 kg
Voltage supply
AC IN voltage
100 – 240 V / max. 500 mA
Line frequency
50 Hz to 60 Hz
Power consumption:
approx. 20 W
Touch current
≤
1 mA
Environmental
Operating temperature:
+0
°
C ... 40
°
C
requirements
Storage/transport temp:
–40
°
C ... 85
°
C
Humidity:
≤
95%, DIN IEC 68-2-14
non-condensing
Electromagnetic
EN 55103-1/-2, EN 55 022, Class B
compability
FCC 47 Part 15
Safety
VDE 0805, EN 60 950
UL 1419
CSA C.22.60950
Interfaces
•
up to 7 intern GPI or 7 intern GPO
GPI: Opto coupler, dry contact or active
(free selectable)
in, max. 20 V
GPO: Silicon switches, potential free,
40V/0.3A.
D-Sub socket 15-pin, female
•
1 Service port (Diagnostic)
D-Sub socket 9-pin, female, RS 232C
•
LAN port (AUI)
D-Sub socket 15-pin, female, by use of
Thin Coax Transceiver
(IEEE 802.3 /10Base-2), cheapernet,
50 ohms, 150m,
with repeater max. 2.5 km,
connect with
Loop – through
•
Genlock
2 BNCs, 50 ohms
•
14 Serial ports
D-sub sockets 9-pin, female,
RS485/422
for UMDs, RSAT 2, RSAT 1 or
Auxiliary panels
•
1 Serial port
D-sub socket 9-pin, female, RS232C
38.4 kbd max.