Maestro — Branding Engine Quick Start Guide
37
Software Upgrade Procedure
CAUTION The following step will cause the control panel to become inoperative while
the update is in progress.
e.
Select
Yes
.
f.
From this point there are several possibilities:
•
A popup will show that the control panel update was suc-
cessful. Repeat
above if another control panel is present.
When all FPGAs/CPLDs have been updated, the v1.5.1
upgrade is complete.
•
An error message may indicate that the “physical JTAG chain is
broken.” The CP Panel Server board, which is located within the
control panel, may need to be replaced. This procedure is
described in Field Modification Note 075079500, Maestro Pro-
cessor Backup Battery, CP Server, and CP FPGA Upgrade. For more
information, contact Technical Support.
g.
An error message may indicate that a module (sub panel) on the
hardware control panel “reported an incorrect module ID.” In this
case, refer to Field Modification Note 075079500, Maestro Processor
Backup Battery, CP Server, and CP FPGA Upgrade.