Linear/luminance key unity clip and gain default, Reset key parameters – Grass Valley M-2100 User Manual
Page 56

2-32
MMCP Installation/Operation Manual
Section 2 — System Operations
2.
Press a
Key Select
button. All setup buttons and knobs associated with
that keyer are changed to a default configuration.
3.
Release the
Key Select
button and its tally will remain what it was before
it was pressed.
Keyer defaults can be set regardless of whether the key is visible on either
the Program or Preset bus. It does not matter when the
Mode/Function
button
is released as long as
Mode/Function
was pressed when the
Key Select
button
was pressed.
This default configuration can be the factory default, or a default configu-
ration defined by the user during system configuration.
Linear/Luminance Key Unity Clip and Gain Default
A keyer must be in modify mode.
1.
Press and hold the
Mode/Function
button.
2.
Press and release the
Linear
button. The tally of the
Linear
button remains
unchanged. The Key Clip and Gain parameters are set to default
values.
Reset Key Parameters
You can reset the current keyer parameters by pressing and holding the
Mode/Function
button and then pressing the appropriate
Key Select
button.
Table 2-5. Factory Default Recall Parameters
Border & Shadow
off (border/shadow luminance = 50%)
External Key
on
Linear Key
on
Clip
50%
Opacity
100%
Matte fill
off
50% Luminance
Hue
Green
Saturation
0%
Unity Gain