Module Installation
Figure 10. Power Supply Locking Pin
Module Installation
There are twelve front slot and twelve rear slot locations in the 2000T3
frame to accommodate either analog or digital modules (refer to
). The 1 RU 2000T1 holds four front and four rear modules (see
). If a front slot module is installed, an appropriate rear connector
module must be installed in the associated rear slot.
Note
Some rear modules are dual height and require 2 slots. This will affect the
number of actual modules that can be installed in the frame. Refer to the spe-
cific module manual for more information.
Input and output configuration is determined by the design of the module
installed. Refer to the appropriate module instruction manual for
input/output configuration information for specific modules.
In the 2000T3 frame, the top slot of the center section (slot 13) is dedicated
to the 2000NET Network Interface Module. The 2000T1 slot #5 accepts the
2000NET module. This module provides intraframe and network commu-
nication and monitoring including the alarm reporting. For additional
information concerning monitoring and control, refer to the 2000NET
Network Interface Module Instruction Manual.
Note
Center slots 14, 16, 17, and 18 are not used in the 2000T3 frame. Even
though some versions of the frame have board-edge guides for these slots,
they should not be used.
Figure 11. 2000T1 Frame Front
Power
supply
locking
slot
8039-10
(2)
(3)
(4)
(5)
(6)
(1)
8039-21
Network Slot (5)
Power Supply Slot (7)
Front Media Slots (1-4)