Kameleon Frames Instruction Manual

Section 2 — Installation

Power Supplies

There are two types of 2000 Series power supplies — one for use in the 3 RU
2000T3 frame (model 2000PS) and one for use in the 1 RU 2000T1 frame
(model 2000PS1D).

CAUTION Check the label at the power supply connector end to verify the type of supply

before installing it in the frame. Keying is used to prevent the insertion of the
wrong supply. Damage to the power supply and frame can result from forcing
the wrong supply into the frame.

Power supplies are shipped separately and should be installed after the
frame is in the equipment rack. In the 2000T3 frame, the top and bottom
frame slots (19 and 21) on the right side are allocated for 2000PS power
supply sleds (see

Figure 9

). The 2000PS sled is keyed for use in the 2000T3

frame only. If the frame has only one power supply sled, it should reside in
slot 19 for maximum cooling. Up to two optional fan modules can be
installed in slots 19, 20, or 21. All three slots will accept a fan module.

Figure 9. 2000 Series Frame

The 1 RU 2000T1 frame uses the single supply sled 2000PS1D containing a
primary and redundant power module. This supply is keyed for insertion
into the 2000T1 frame only.

To install a power supply:

1.

Remove the frame front cover.

2.

Slide the supply sled into the desired slot holding the spring tensioned
locking handle to the left (see

Figure 10 on page 29

).

3.

Lock the supply in place. The handle locking pins slide into the slot in
the side of the frame.

(2)

(3)

(4)

(5)

(6)

(7)

(8)

(9)

(10)

(11)

(12)

(15)

(13)

(1)

8039-04

Network Slot (13)

Reference Distribution Slot (15)

Main Power Supply Slot (19)

Redundant Power

Supply Slot (21)

Front Media Slots (1-12)

Slot (20)