Power, Cooling, and Module Capacity
provides maximum power usage per module slot for adequate
cooling in the frame. Frame, power supply and fan configurations are
described for the 2000T3 and the 2000T1 frames with 2000NET, 2000GEN,
and front media modules.
Table 2. Power, Cooling, and Module Capacity of 2000 Frames
Capacity Calculated
2000T1with
Dual Power
Supply Sled
2000T3 with
Single Power
Supply Sled
2000T3 with
Two Power
Supply Sleds
2000T3 with
Single Power
Supply Sled and a
Fan Assembly
Power (W)
95 W
165 W
212 W
240W
Recommended maximum power per front module to ensure ade-
quate cooling
16 W
12 W
17.5 W
16 W
Recommended maximum power per rear module to ensure ade-
quate cooling
8 W
6 W
8 W
8 W
Recommended maximum slot power to ensure adequate cooling
20 W
12 W
17.5 W
17.5 W
Power supply load dissipated by power supply sled
4.6 W (fans)
Power supply load dissipated by fan module
N/A
4.6 W
Recommended maximum 2000NET module slot power to ensure
adequate cooling
5 W
5 W
Recommended maximum2000GEN module slot power to ensure
adequate cooling
5 W
5 W
Recommended maximum front media module slot power to
ensure adequate cooling
Refer to specific module instruction manual for power usage and maximum rec-