23

Power, Cooling, and Module Capacity

Table 2

provides maximum power usage per module slot for adequate

cooling in the frame. Frame, power supply and fan configurations are
described for the 2000T3 and the 2000T1 frames with 2000NET, 2000GEN,
and front media modules.

Table 2. Power, Cooling, and Module Capacity of 2000 Frames

Capacity Calculated

2000T1with

Dual Power

Supply Sled

2000T3 with

Single Power

Supply Sled

2000T3 with

Two Power

Supply Sleds

2000T3 with

Single Power

Supply Sled and a

Fan Assembly

Power (W)

95 W

165 W

212 W

240W

Recommended maximum power per front module to ensure ade-
quate cooling

16 W

12 W

17.5 W

16 W

Recommended maximum power per rear module to ensure ade-
quate cooling

8 W

6 W

8 W

8 W

Recommended maximum slot power to ensure adequate cooling

20 W

12 W

17.5 W

17.5 W

Power supply load dissipated by power supply sled

4.6 W (fans)

Power supply load dissipated by fan module

N/A

4.6 W

Recommended maximum 2000NET module slot power to ensure
adequate cooling

5 W

5 W

Recommended maximum2000GEN module slot power to ensure
adequate cooling

5 W

5 W

Recommended maximum front media module slot power to
ensure adequate cooling

Refer to specific module instruction manual for power usage and maximum rec-
ommended modules per frame.