Monitoring and control – Grass Valley 2000T3 User Manual
Page 19

Kameleon Frames Instruction Manual
19
2000 Series Frame Options
When the 2000T3 Series frame is loaded with modules that require
greater than 150 Watts of power and only one power supply sled is
installed, a fan module is required for adequate cooling. The 2000FAN
sled normally resides between the two power supply slots shown in
. If extra cooling is desired and the frame operates on only one
power supply sled, a second fan sled can be placed in either power
supply slot. Refer to
Power, Cooling, and Module Capacity on page 22
.
Figure 3. T3 Frame Fan Module Slot
Monitoring and Control
The 2000 Series frame offers extensive control and monitoring capability
when the 2000 Network Interface Module option (2000NET) is added.
The 2000NET Network Interface Module supports the frame connections
for:
•
Frame Health alarm relay (2000T3 frames only),
•
Frame network configuration serial port, and
•
Ethernet 10Base-T connection for Grass Valley Modular Control and
Monitoring System (web browser-based GUI) and Newton Control
System.
The 2000NET module also provides DIP switches for enabling and dis-
abling alarms, and LED indicators for quick diagnostics of alarm condi-
tions related to temperature, power supply health, frame bus
communications and module error reporting. For detailed information on
the 2000NET module and GUI refer to the 2000NET Network Interface
Module Instruction Manual available on-line.
Up to two optional
fan modules can
be installed.
Each slot
(19, 20, 21)
can accept
a fan module.
Power Supply
Slot 19
Power Supply
Slot 21
Slot 20
8039-05