02 February 2012

K2 Dyno Replay Controller Service Manual

49

Run hardware diagnostics (software version 2.x)

• the T-Bar position information is correct

• the hardware responds to the JOG operations properly

NOTE: In version 2.x, the jog knob is no longer based on speed. Instead, it is based
on the position. For example, if you turn the knob one revolution, then go back one
revolution, you are back at the original location.

• the touch panel detects correct positions

• the touch panel brightness can be changed

1. While in a regular Dyno software session, touch

Config | Exit

and select the option

for Maintenance mode.

The Windows desktop displays.

2. To start the diagnostics tool, double-click ControllerDiag.exe in c:/program

files/Grass Valley/Dyno

The Diagnostics screen appears.

3. Perform hardware operation checks.

NOTE: Any changes made in the diagnostics, such as button brightness changes,
will be disabled when you exit the diagnostics.Changes, such as brightness changes
and lever position adjustments, must be made in a calibration.

4. When finished, click the

Exit

button at the upper right side.

5. When you exit the diagnostics, you are returned to the Windows desktop. To

re-start the Dyno software, click on the Dyno icon on the desktop.