8964ENC/-FS — Instruction Manual
Service
Service
The 8964ENC modules make extensive use of surface-mount technology
and programmed parts to achieve compact size and adherence to
demanding technical specifications. Circuit modules should not be ser-
viced in the field unless directed otherwise by Customer Service.
If your module is not operating correctly, proceed as follows:
•
Check frame and module power and signal present LEDs.
•
Verify power at the voltage testpoints (see
) and check Fuse if
no voltage is detected.
•
Check for presence and quality of input signals.
•
Verify that source equipment is operating correctly.
•
Check cable connections.
•
Check output connections for correct I/O mapping (correct input con-
nector is used for the corresponding channel output).
for the location of PWR LED and
for
proper LED indications.
If the module is still not operating correctly, replace it with a known good
spare and return the faulty module to a designated Grass Valley repair
depot. Call your Grass Valley representative for depot location.
Refer to the Contacting Grass Valley
at the front of this document
for the Grass Valley Customer Service Information number.
Figure 32. 8964ENC Fuse and Voltage Testpoint Locations
8209_09
r2
Voltage Testpoints
J1
+5V
–5V
+3.3V
+1.5V
Fuse: 2 A 125 V
F2