Configuration, Configuration summary, Video timing and freeze controls – Grass Valley 8964ENC v.1.2.2 User Manual
Page 20

20
8964ENC/-FS — Instruction Manual
Configuration
Configuration
The 8964ENC can be configured locally using onboard switches or
remotely using the 8900NET network interface GUI or a networked control
panel.
Refer to the following sections for configuration instructions:
•
Configuration Summary (
)
•
Local Onboard Module Configuration (
•
Remote Control and Monitoring (
Operation of these control types is explained in detail in their respective
sections of this manual.
Table 8 on page 67
provides a summary in table
format of all parameters and their ranges, default values, and remote, local,
and control panel function names and locations for setting each value.
Configuration Summary
This section provides a summary of all parameters that can be configured
on the 8964ENC module. The video processing configuration is described
by what line types will be affected by the adjustments or choices made. Use
this section in conjunction with the specific configuration method instruc-
tions for each configuration type.
Video Timing and Freeze Controls
With a standard 8964ENC module with no Frame Sync the following line
sync timing adjustments are available:
•
Horizontal Timing – adjusts the horizontal delay of the channel output
in half pixels. and
•
Fine Phase Adjustment – adjusts the horizontal fine phase relative to
the input sync reference (in percent of 37 ns).
With an 8964ENC-FS module (8964ENC with Frame Sync, see
), the following vertical timing adjustments can
be made:
•
Horizontal Timing – identical to the line sync timing above.
•
Fine Phase Adjustment – identical to the fine phase timing above.
•
Vertical Timing – adjusts vertical delay in line increments.